Short-Form System Reference Guide: Architectural Interior and Exterior Coatings
Use this guide to choose a coating system by substrate, exposure and service condition. It is a selection reference, not a bid-ready specification. The full guide is below, and a PDF copy is free to download.
Download the PDF: the file is attached at the end of this page.
For bid documents: use the companion Section 09 96 00 High-Performance Coatings guide specification, or ask ACC for a specification tailored to your project.
Questions: atlantic@tnemec.com or 484-644-5303.
Reader's Note
Use this guide to quickly select an architectural coating system by substrate, exposure, and service condition. It is a selection reference for architects, engineers, facilities/asset managers, and project teams; it is not a bid-ready specification.
For bid or construction documents, use the companion CSI 3-part specification, Section 09 96 00 - High-Performance Coatings, or contact ACC for project-specific guidance.
Prepared as a service by: Atlantic Coating Consultants | Wally Bates | atlantic@tnemec.com | 484-644-5303
Overview
1. Purpose
This guide summarizes commonly used architectural interior and exterior coating systems for concrete/CMU, structural and miscellaneous metals, concrete ceilings, glazed tile, wood, PVC, stucco, metal panels, doors/frames, pedestrian decks, sealers and related building surfaces. Systems are organized by substrate and exposure so they can be used across institutional, municipal, commercial, and similar facilities.
2. How to Use This Guide
• Start with the Quick Locator Index if you know the substrate or building component. Find the applicable system in the schedule below.
• If you know the substrate and exposure, go directly to the system tables and match the Condition and Typical Locations.
• Use Surface Preparation, Coat Schedule, and Total Build for budgeting, work-order planning, and contractor pricing.
• Contact ACC to confirm project-specific exposure, existing coating condition, color/gloss, aesthetics, or full CSI specification requirements.
3. Basis of Design
Products scheduled herein are manufactured by Tnemec Company, Inc. (with select exterior metal-panel-roof and water-repellent systems by Tex-Cote LLC, noted where used) and are listed as the basis of design for the performance, appearance, and warranty characteristics described.
4. Not Covered in This Guide
Typical Locations are intentionally broad so the guide can be used across building types. Resinous flooring systems are in the companion Short-Form System Reference Guide — Resinous Flooring. Facility-specific process systems are maintained in the separate ACC water and wastewater references.
5. General Application & Warranty Notes
• Follow the current manufacturer product data sheet for substrate, ambient, dew-point, humidity, ventilation, surface-profile, and application requirements.
• Verify dry film thickness during and after application. For decorative, reinforced, or resinous systems, consider a mock-up or field sample before full-scale application.
• Concrete/CMU surface-profile requirements vary by system; confirm the specified ICRI CSP and verify surface preparation before full-scale work.
• Confirm optional topcoats, alternate finishes, color, and gloss selections with the Owner/Architect before ordering or application.
• Warranty terms vary by system and project; contact ACC or the manufacturer to confirm applicable coverage, including exterior metal-panel color/gloss warranty options.
Quick Locator Index
Find a system by substrate or building component. Confirm project-specific conditions before final selection.
System Group | Applicable System |
INTERIOR SYSTEMS | |
CMU / CONCRETE WALLS | New or Uncoated CMU — Light Architectural Duty New or Uncoated CMU — Moderate Duty, Water Based New or Uncoated CMU — Moderate Duty, Solvent Based New or Uncoated CMU — Moderate/Heavy Duty, Water Based w/ Urethane Finish New or Uncoated CMU — Moderate/Heavy Duty, 100% Solids Epoxy w/ Urethane Finish New or Uncoated CMU — Moderate/Heavy Duty, Chemical Resistant New or Uncoated CMU — Heavy Duty / Washdown, 100% Solids Reinforced New or Uncoated Concrete — Light Duty New or Uncoated Concrete — Moderate Duty, Water Based New or Uncoated Concrete — Moderate Duty, Solvent Based New or Uncoated Concrete — Moderate/Heavy Duty, Water Based w/ Urethane Finish New or Uncoated Concrete — Moderate/Heavy Duty, 100% Solids Epoxy w/ Urethane Finish New or Uncoated Concrete — Moderate/Heavy Duty, Chemical Resistant Previously Painted CMU/Concrete — Light Duty Previously Painted CMU/Concrete — Moderate Duty, Water Based Previously Painted CMU/Concrete — Moderate Duty, Solvent Based Previously Painted CMU/Concrete — Moderate/Heavy Duty, Water Based w/ Urethane Finish Previously Painted CMU/Concrete — Moderate/Heavy Duty, 100% Solids Epoxy w/ Urethane Finish Previously Painted CMU/Concrete — Moderate/Heavy Duty, Chemical Resistant |
STRUCTURAL STEEL | New or Uncoated Steel — Moderate Duty, Solvent Based Epoxy New or Uncoated Steel — Moderate Duty, Solvent Based Epoxy w/ Urethane Finish New or Uncoated Steel — Heavy Duty, Chemical Resistant Epoxy New or Uncoated Steel — Overhead Structural Steel / Joists / Deck, Dry-Fall Previously Painted Steel — Moderate Duty, Solvent Based Epoxy Finish Previously Painted Steel — Moderate Duty, Solvent Based Epoxy w/ Urethane Finish Previously Painted Steel — Heavy Duty, Chemical Resistant Epoxy Previously Painted Steel — Overhead Structural Steel / Joists / Deck, Dry-Fall |
STEEL RAILINGS & HANDRAILS | New or Uncoated Steel — Light Architectural Duty Previously Painted Steel — Light Architectural Duty Previously Painted Steel — Hollow Metal Doors, Frames, Railings — Light Architectural Duty Previously Painted Steel — Hollow Metal Doors, Frames, Railings — Moderate/Heavy Duty |
GALVANIZED STEEL & ALUMINUM — INTERIOR | New or Uncoated Steel — Galvanized Steel, Epoxy Finish New or Uncoated Steel — Galvanized Steel, Urethane Finish New or Uncoated Steel — Galvanized Steel, Light Architectural Duty Previously Painted Steel — Galvanized Steel, Epoxy Finish Previously Painted Steel — Galvanized Steel, Urethane Finish Interior Aluminum and Non-Ferrous Metal |
CONCRETE PLANK CEILINGS | Dry-Fall, High-Moisture / Natatorium Ceilings Flexible / Mildew-Resistant Ceilings (Locker Rooms) |
GYPSUM BOARD | Gypsum board systems are not covered in this guide; contact ACC for a project-specific recommendation. |
GLAZED TILE | Light/Moderate Duty Moderate/Heavy Duty, Epoxy w/ Urethane Finish Shower / Wet Walls |
WOOD (BARE OR PREVIOUSLY PAINTED) | Wood — Bare or Previously Painted |
PVC | PVC Pipe, Trim and Plastic Components Insulated Pipe Jacketing (Canvas / PVC Jacket) |
EXTERIOR SYSTEMS | |
STRUCTURAL / ARCHITECTURALLY EXPOSED STEEL | New or Full Coating Removal — Zinc / Epoxy / Urethane (Good) New or Full Coating Removal — Zinc / Epoxy / Urethane / Fluoropolymer (Best — Extended UV & Color Retention) Overcoat — Epoxy Mastic / Urethane (Good) Overcoat — Epoxy Mastic / Urethane / Fluoropolymer (Best) |
STEEL RAILINGS — EXTERIOR | New or Full Coating Removal — Zinc / Epoxy / Urethane (Good) New or Full Coating Removal — Zinc / Epoxy / Urethane / Fluoropolymer (Best — Extended UV & Color Retention) Hollow Metal Doors, Frames, Railings — Light Architectural Duty Hollow Metal Doors, Frames, Railings — Moderate/Heavy Duty |
System Group | Applicable System — Click to Jump |
GALVANIZED STEEL — EXTERIOR | New or Full Coating Removal, Urethane Finish (Good) New or Full Coating Removal, Fluoropolymer Finish (Best) Previously Coated Galvanized, Overcoat |
ALUMINUM — EXTERIOR | General |
CMU / CONCRETE WALLS — ELASTOMERIC / CRACK-BRIDGING | Uncoated — Elastomeric / Crack-Bridging, Smooth Finish Uncoated — Elastomeric / Crack-Bridging, Sand Textured Finish Previously Painted — Elastomeric / Crack-Bridging Recoat |
CMU / CONCRETE WALLS — BREATHABLE COATING SYSTEM | Uncoated — Series 156 Enviro-Crete, Smooth Finish Uncoated — Series 156/157 Enviro-Crete, Sand Textured Finish Previously Painted — Series 156 Enviro-Crete Recoat Stucco — Series 156 Enviro-Crete |
STUCCO | Uncoated or Previously Painted |
WOOD — EXTERIOR | Bare or Previously Painted |
METAL PANEL ROOFS & WALLS — BEST (15-YEAR COLOR & GLOSS WARRANTY) | Best — 15-Year Color and Gloss |
METAL PANEL ROOFS & WALLS — GOOD (7-YEAR COLOR & GLOSS WARRANTY) | Good — 7-Year Color and Gloss |
HOLLOW METAL DOORS AND FRAMES — EXTERIOR | Hollow Metal Doors, Frames, Railings — Light Architectural Duty Hollow Metal Doors, Frames, Railings — Moderate/Heavy Duty |
PEDESTRIAN DECK COATING (NON-VEHICULAR) | General Waterproofing, Broadcast Exposed Concrete Stairs and Elevated Decks, Mesh-Reinforced |
WATER REPELLENTS & SEALERS | Penetrating Silane/Siloxane Water Repellent Anti-Graffiti (Sacrificial / Non-Sacrificial) |
RESINOUS FLOORING | |
EPOXY BROADCAST SYSTEMS | Epoxy broadcast floor systems (100% solids and water-based) are in the companion Short-Form System Reference Guide — Resinous Flooring (Section 09 67 23). |
URETHANE CEMENT SYSTEMS | Urethane cement floor systems are in the companion Short-Form System Reference Guide — Resinous Flooring (Section 09 67 23). |
REINFORCED WATERPROOF DECK COATING | The reinforced waterproof deck coating is in the companion Short-Form System Reference Guide — Resinous Flooring (Section 09 67 23). |
SPECIALTY SYSTEMS | |
THERMAL-BREAK COATINGS | Aerogel Thermal-Break Coating at Steel Envelope Penetrations |
Architectural Interior & Exterior Coating Systems
Includes interior systems for CMU, concrete, ceilings, steel, galvanized and non-ferrous metal, glazed tile, wood and PVC; exterior systems for masonry, stucco, steel, galvanized, aluminum, doors and frames, metal panels, wood, pedestrian decks and sealers; and specialty systems. Based on Section 09 96 00.
Condition | Typical Locations | Surface Preparation | Coat Schedule (Product — DFT) | Total Build |
INTERIOR SYSTEMS | ||||
C1 — NEW OR PREVIOUSLY UNCOATED CMU | ||||
Light Architectural Duty C1.1 | Offices, corridors, classrooms, conference rooms, storage and other low-abuse interior block walls receiving a breathable acrylic finish | Clean and dry; allow new CMU and mortar to cure a minimum of 28 days; remove efflorescence, loose mortar and dust | Block Filler: Series 130 Envirofill — 60–80 SF/gal First Coat: Series 1026 Enduratone — 2.0–3.0 mils DFT Finish Coat: Series 1026 Enduratone — 2.0–3.0 mils DFT | 4.0–6.0 mils DFT (over block filler applied at coverage rate) |
Moderate Duty, Water Based C1.2 | Storage rooms, mechanical/electrical rooms, utility rooms, workshops, service areas and general-use uncoated block walls | Clean and dry; allow new CMU and mortar to cure a minimum of 28 days; remove efflorescence, loose mortar and dust | Block Filler: Series 130 Envirofill — 60–80 SF/gal First Coat: Series 288/289 Enviro-Pox — 4.0–6.0 mils DFT Finish Coat: Series 288/289 Enviro-Pox — 4.0–6.0 mils DFT | 8.0–12.0 mils DFT (over block filler applied at coverage rate) |
Moderate Duty, Solvent Based C1.3 | Mechanical/electrical rooms, workshops, garages, storage and service areas where a solvent-based epoxy finish is acceptable and low odor is not required | Clean and dry; allow new CMU and mortar to cure a minimum of 28 days; remove efflorescence, loose mortar and dust | Block Filler: Series 130 Envirofill — 60–80 SF/gal First Coat: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT Finish Coat: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT | 8.0–12.0 mils DFT (over block filler applied at coverage rate) |
Moderate/Heavy Duty, Water Based w/ Urethane Finish C1.4 | Locker rooms, restrooms, kitchens, corridors, custodial and service areas needing a scrubbable, color-retentive urethane finish over low-odor epoxy | Clean and dry; allow new CMU and mortar to cure a minimum of 28 days; remove efflorescence, loose mortar and dust | Block Filler: Series 130 Envirofill — 60–80 SF/gal First Coat: Series 288/289 Enviro-Pox — 4.0–6.0 mils DFT Finish Coat: Series 297 Enviro-Glaze — 2.0–3.0 mils DFT | 6.0–9.0 mils DFT (over block filler applied at coverage rate) |
Moderate/Heavy Duty, 100% Solids Epoxy w/ Urethane Finish C1.5 | Laboratories, kitchens, washdown rooms, corridors and high-abuse areas where a 100% solids epoxy build and urethane finish are required | Clean and dry; allow new CMU and mortar to cure a minimum of 28 days; remove efflorescence, loose mortar and dust | Block Filler: Series 1254 Epoxoblock WB — ~100 SF/gal (CMU) First Coat: Series 280 Tneme-Glaze — 4.0–6.0 mils DFT Finish Coat: Series 297 Enviro-Glaze — 2.0–3.0 mils DFT | 6.0–9.0 mils DFT (over block filler applied at coverage rate) |
Moderate/Heavy Duty, Chemical Resistant C1.6 | Chemical storage and feed rooms (non-immersion), laboratories, battery rooms, wash bays and areas subject to chemical splash or frequent washdown | Clean and dry; allow new CMU and mortar to cure a minimum of 28 days; remove efflorescence, loose mortar and dust | Block Filler: Series 130 Envirofill — 60–80 SF/gal First Coat: Series 104 H.S. Epoxy — 4.0–6.0 mils DFT Finish Coat: Series 104 H.S. Epoxy — 4.0–6.0 mils DFT | 8.0–12.0 mils DFT (over block filler applied at coverage rate) |
Heavy Duty / Washdown, 100% Solids Reinforced C1.7 | High-traffic corridors, secure or controlled-access areas, maintenance/service spaces, wet areas, laboratories and walls subject to repeated impact or abuse | Clean and dry; allow new CMU and mortar to cure a minimum of 28 days; remove efflorescence, loose mortar and dust | Filler: Series 215 Surfacing Epoxy — 25–40 SF/gal Glass Mat: Series 273 ML Stranlok, embedded into wet Series 215 Saturant: Series 280 Tneme-Glaze — 8.0–10.0 mils DFT Intermediate: Series 280 Tneme-Glaze — 6.0–8.0 mils DFT Finish Coat: Series 297 Enviro-Glaze — 2.0–3.0 mils DFT | 16.0–21.0 mils DFT (over surfacer/filler applied as needed — not a rated coat) |
C2 — NEW OR PREVIOUSLY UNCOATED CONCRETE | ||||
Light Duty C2.1 | Offices, corridors, storage and other low-abuse interior poured or precast concrete walls | SSPC-SP13/NACE No. 6 Surface Preparation of Concrete; ICRI-CSP 2-3; clean, dry, cured a minimum of 28 days | Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT Filler (as needed): Series 215 Surfacing Epoxy — Applied at coverage rate First Coat: Series 1026 Enduratone — 2.0–3.0 mils DFT Finish Coat: Series 1026 Enduratone — 2.0–3.0 mils DFT | 4.7–7.5 mils DFT (over surfacer/filler applied as needed — not a rated coat) |
Moderate Duty, Water Based C2.2 | Basements, utility rooms, service corridors, mechanical rooms and general interior poured or precast concrete walls in occupied facilities | SSPC-SP13/NACE No. 6 Surface Preparation of Concrete; ICRI-CSP 2-3; clean, dry, cured a minimum of 28 days | Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT Filler (as needed): Series 215 Surfacing Epoxy — Applied at coverage rate First Coat: Series 288/289 Enviro-Pox — 4.0–6.0 mils DFT Finish Coat: Series 288/289 Enviro-Pox — 4.0–6.0 mils DFT | 8.7–13.5 mils DFT (over surfacer/filler applied as needed — not a rated coat) |
Moderate Duty, Solvent Based C2.3 | Mechanical/electrical rooms, workshops, garages, service and process support areas with interior concrete walls where low odor is not required | SSPC-SP13/NACE No. 6 Surface Preparation of Concrete; ICRI-CSP 2-3; clean, dry, cured a minimum of 28 days | Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT Filler (as needed): Series 215 Surfacing Epoxy — Applied at coverage rate First Coat: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT Finish Coat: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT | 8.7–13.5 mils DFT (over surfacer/filler applied as needed — not a rated coat) |
Moderate/Heavy Duty, Water Based w/ Urethane Finish C2.4 | Locker rooms, restrooms, kitchens, corridors and frequently cleaned interior concrete walls needing a urethane finish | SSPC-SP13/NACE No. 6 Surface Preparation of Concrete; ICRI-CSP 2-3; clean, dry, cured a minimum of 28 days | Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT Filler (as needed): Series 215 Surfacing Epoxy — Applied at coverage rate First Coat: Series 288/289 Enviro-Pox — 4.0–6.0 mils DFT Finish Coat: Series 297 Enviro-Glaze — 2.0–3.0 mils DFT | 6.7–10.5 mils DFT (over surfacer/filler applied as needed — not a rated coat) |
Moderate/Heavy Duty, 100% Solids Epoxy w/ Urethane Finish C2.5 | Laboratories, washdown rooms, process support spaces and high-abuse interior concrete walls requiring a 100% solids epoxy build and urethane finish | SSPC-SP13/NACE No. 6 Surface Preparation of Concrete; ICRI-CSP 2-3; clean, dry, cured a minimum of 28 days | Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT Filler (as needed): Series 215 Surfacing Epoxy — Applied at coverage rate First Coat: Series 280 Tneme-Glaze — 4.0–6.0 mils DFT Finish Coat: Series 297 Enviro-Glaze — 2.0–3.0 mils DFT | 6.7–10.5 mils DFT (over surfacer/filler applied as needed — not a rated coat) |
Moderate/Heavy Duty, Chemical Resistant C2.6 | Chemical rooms (non-immersion), laboratories, wash bays and interior concrete walls subject to chemical splash or frequent washdown | SSPC-SP13/NACE No. 6 Surface Preparation of Concrete; ICRI-CSP 2-3; clean, dry, cured a minimum of 28 days | Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT Filler (as needed): Series 215 Surfacing Epoxy — Applied at coverage rate First Coat: Series 104 H.S. Epoxy — 4.0–6.0 mils DFT Finish Coat: Series 104 H.S. Epoxy — 4.0–6.0 mils DFT | 8.7–13.5 mils DFT (over surfacer/filler applied as needed — not a rated coat) |
C3 — EXISTING / PREVIOUSLY PAINTED CMU AND CONCRETE | ||||
Light Duty C3.1 | Previously painted offices, corridors, classrooms, storage and other low-abuse interior CMU or concrete walls | SSPC-SP1; remove chalk/loose paint, patch cracks, spot prime bare areas, dull glossy surfaces | Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT Filler (as needed): Series 215 Surfacing Epoxy — Applied at coverage rate First Coat: Series 1026 Enduratone — 2.0–3.0 mils DFT Finish Coat: Series 1026 Enduratone — 2.0–3.0 mils DFT | 4.7–7.5 mils DFT (over surfacer/filler applied as needed — not a rated coat) |
Moderate Duty, Water Based C3.2 | Previously painted corridors, restrooms, break rooms, utility and service areas receiving a low-odor epoxy maintenance coating | SSPC-SP1; remove chalk/loose paint, patch cracks, spot prime bare areas, dull glossy surfaces | Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT Filler (as needed): Series 215 Surfacing Epoxy — Applied at coverage rate First Coat: Series 288/289 Enviro-Pox — 4.0–6.0 mils DFT Finish Coat: Series 288/289 Enviro-Pox — 4.0–6.0 mils DFT | 8.7–13.5 mils DFT (over surfacer/filler applied as needed — not a rated coat) |
Moderate Duty, Solvent Based C3.3 | Previously painted mechanical rooms, workshops, garages and service areas where a solvent-based epoxy recoat is acceptable | SSPC-SP1; remove chalk/loose paint, patch cracks, spot prime bare areas, dull glossy surfaces | Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT Filler (as needed): Series 215 Surfacing Epoxy — Applied at coverage rate First Coat: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT Finish Coat: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT | 8.7–13.5 mils DFT (over surfacer/filler applied as needed — not a rated coat) |
Moderate/Heavy Duty, Water Based w/ Urethane Finish C3.4 | Previously painted locker rooms, restrooms, kitchens, corridors and frequently cleaned walls needing a urethane finish | SSPC-SP1; remove chalk/loose paint, patch cracks, spot prime bare areas, dull glossy surfaces | Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT Filler (as needed): Series 215 Surfacing Epoxy — Applied at coverage rate First Coat: Series 288/289 Enviro-Pox — 4.0–6.0 mils DFT Finish Coat: Series 297 Enviro-Glaze — 2.0–3.0 mils DFT | 6.7–10.5 mils DFT (over surfacer/filler applied as needed — not a rated coat) |
Moderate/Heavy Duty, 100% Solids Epoxy w/ Urethane Finish C3.5 | Previously painted laboratories, washdown rooms and high-abuse walls requiring a 100% solids epoxy build and urethane finish | SSPC-SP1; remove chalk/loose paint, patch cracks, spot prime bare areas, dull glossy surfaces | Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT Filler (as needed): Series 215 Surfacing Epoxy — Applied at coverage rate First Coat: Series 280 Tneme-Glaze — 4.0–6.0 mils DFT Finish Coat: Series 297 Enviro-Glaze — 2.0–3.0 mils DFT | 6.7–10.5 mils DFT (over surfacer/filler applied as needed — not a rated coat) |
Moderate/Heavy Duty, Chemical Resistant C3.6 | Previously painted chemical rooms (non-immersion), laboratories, wash bays and walls subject to chemical splash or washdown | SSPC-SP1; remove chalk/loose paint, patch cracks, spot prime bare areas, dull glossy surfaces | Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT Filler (as needed): Series 215 Surfacing Epoxy — Applied at coverage rate First Coat: Series 104 H.S. Epoxy — 4.0–6.0 mils DFT Finish Coat: Series 104 H.S. Epoxy — 4.0–6.0 mils DFT | 8.7–13.5 mils DFT (over surfacer/filler applied as needed — not a rated coat) |
C4 — CONCRETE CEILINGS – NEW, EXISTING PAINTED OR STRUCTURAL, PLANK AND DECK | ||||
Dry-Fall, High-Moisture / Natatorium Ceilings C4.1 | Pool or aquatic areas, high-humidity mechanical rooms, laundry areas, wash bays, wet-process rooms and persistently humid interior spaces | SSPC-SP13/NACE No. 6; clean and dry; remove loose/peeling coating on previously painted ceilings | Primer: Series 115 Uni-Bond DF — 2.0–4.0 mils DFT Intermediate: Series 115 Uni-Bond DF — 2.0–4.0 mils DFT Finish Coat: Series 115 Uni-Bond DF — 2.0–4.0 mils DFT | 6.0–12.0 mils DFT |
Flexible / Mildew-Resistant Ceilings (Locker Rooms) C4.2 | Locker rooms, showers, laundry rooms, restrooms, wash areas and intermittently humid interior spaces | SSPC-SP13/NACE No. 6; clean and dry; remove loose/peeling coating on previously painted ceilings | Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT First Coat: Series 158 Bio-Lastic — 6.0–7.0 mils DFT Finish Coat: Series 158 Bio-Lastic — 6.0–7.0 mils DFT | 12.7–15.5 mils DFT |
S1 — NEW OR PREVIOUSLY UNCOATED STEEL | ||||
Light Architectural Duty S1.1 | Doors and frames, railings, trim, miscellaneous metals and exposed steel in offices and other low-abuse interior spaces | SSPC-SP1 Solvent Cleaning; SSPC-SP2/SP3 Hand/Power Tool Cleaning minimum (SSPC-SP6 preferred) | Primer: Series V10 Tnemec Primer — 2.0–3.5 mils DFT Touch-Up Primer: Series V10 Tnemec Primer — 2.0–3.5 mils DFT First Coat: Series 1026 Enduratone — 2.0–3.0 mils DFT Finish Coat: Series 1026 Enduratone — 2.0–3.0 mils DFT | 6.0–9.5 mils DFT (excludes touch-up coats) |
Moderate Duty, Solvent Based Epoxy S1.2 | Structural steel, columns, beams, equipment supports, platforms and miscellaneous steel in mechanical rooms, garages, shops and process support areas | SSPC-SP6/NACE No. 3 Commercial Blast Cleaning | Primer: Series 1 Omnithane — 2.5–3.5 mils DFT Touch-Up Primer: Series 1 Omnithane — 2.5–3.5 mils DFT First Coat: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT Finish Coat: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT Note: Specify Series 90-97 Tneme-Zinc for natatorium and/or wet environments. | 10.5–15.5 mils DFT (excludes touch-up coats) |
Moderate Duty, Solvent Based Epoxy w/ Urethane Finish S1.3 | Exposed structural steel, stairs, railings, mezzanines and equipment in lobbies, gymnasiums, corridors and other visible interior spaces needing color and gloss retention | SSPC-SP6/NACE No. 3 Commercial Blast Cleaning | Primer: Series 1 Omnithane — 2.5–3.5 mils DFT Touch-Up Primer: Series 1 Omnithane — 2.5–3.5 mils DFT First Coat: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT Finish Coat: Series 1095 Endura-Shield — 3.0–4.0 mils DFT Note: Specify Series 90-97 Tneme-Zinc for natatorium and/or wet environments. Note: Use Series 1090 as the finish coat for high traffic areas | 9.5–13.5 mils DFT (excludes touch-up coats) |
Heavy Duty, Chemical Resistant Epoxy S1.4 | Steel in chemical rooms, laboratories, wash bays and process areas subject to chemical splash, fumes or frequent washdown (non-immersion) | SSPC-SP10/NACE No. 2 Near-White Metal Blast Cleaning | Primer: Series 1 Omnithane — 2.5–3.5 mils DFT Touch-Up Primer: Series 1 Omnithane — 2.5–3.5 mils DFT Stripe Coat: Series 104 H.S. Epoxy — 4.0–6.0 mils DFT First Coat: Series 104 H.S. Epoxy — 4.0–6.0 mils DFT Finish Coat: Series 104 H.S. Epoxy — 4.0–6.0 mils DFT | 10.5–15.5 mils DFT (excludes stripe/touch-up coats) |
Overhead Structural Steel / Joists / Deck, Dry-Fall S1.5 | Overhead structural steel, bar joists, metal deck, ductwork and conduit in gymnasiums, warehouses, shops and open-ceiling spaces (dry-fall application) | SSPC-SP6/NACE No. 3 Commercial Blast Cleaning | Primer: Series 1 Omnithane — 2.5–3.5 mils DFT Touch-Up Primer: Series 1 Omnithane — 2.5–3.5 mils DFT First Coat: Series 115 Uni-Bond DF — 2.0–4.0 mils DFT Finish Coat: Series 115 Uni-Bond DF — 2.0–4.0 mils DFT Note: Specify Series 90-97 Tneme-Zinc for natatorium and/or wet environments. | 6.5–11.5 mils DFT (excludes touch-up coats) |
Galvanized Steel, Epoxy Finish S1.6 | Galvanized pipe, handrails, ladders and miscellaneous fabrications — interior, non-immersion service | SSPC-SP1 to remove oil/grease/contaminants; SSPC-SP16 to remove storage stains and uniformly profile | First Coat: Series V69 Hi-Build Epoxoline II — 3.0–4.0 mils DFT Finish Coat: Series V69 Hi-Build Epoxoline II — 3.0–4.0 mils DFT | 6.0–8.0 mils DFT |
Galvanized Steel, Urethane Finish S1.7 | Exposed galvanized railings, stairs, ladders, frames and miscellaneous fabrications in visible interior spaces needing color and gloss retention | SSPC-SP1 to remove oil/grease/contaminants; SSPC-SP16 to remove storage stains and uniformly profile | First Coat: Series V69 Hi-Build Epoxoline II — 3.0–4.0 mils DFT Finish Coat: Series 1095 Endura-Shield — 3.0–4.0 mils DFT | 6.0–8.0 mils DFT |
Galvanized Steel, Light Architectural Duty S1.8 | Railings, stairs, ladders, supports, equipment frames, guards and miscellaneous galvanized or nonferrous metal | SSPC-SP1 to remove oil/grease/contaminants; SSPC-SP16 to remove storage stains and uniformly profile | Primer: Series 116 Uni-Bond — 2.0–4.0 mils DFT Finish Coat: Series 1028 Enduratone — 2.0–3.0 mils DFT | 4.0–7.0 mils DFT |
S2 — EXISTING / PREVIOUSLY PAINTED STEEL | ||||
Light Architectural Duty S2.1 | Previously painted doors and frames, railings, trim and miscellaneous metals in low-abuse interior spaces | Wash clean; SSPC-SP2/SP3 Hand/Power Tool Cleaning to degloss; remove loose coatings; feather transition edges | Spot Primer: Series V10 Tnemec Primer — 2.0–3.5 mils DFT First Coat: Series 1026 Enduratone — 2.0–3.0 mils DFT Finish Coat: Series 1026 Enduratone — 2.0–3.0 mils DFT | 6.0–9.5 mils DFT |
Moderate Duty, Solvent Based Epoxy Finish S2.2 | Previously painted structural steel, equipment supports, platforms and miscellaneous steel in mechanical rooms, garages, shops and process support areas | Wash clean; SSPC-SP2/SP3 Hand/Power Tool Cleaning to degloss; remove loose coatings; feather transition edges | Spot Prime: Series 135 Chembuild — 4.0–6.0 mils DFT First Coat: Series 135 Chembuild — 4.0–6.0 mils DFT Finish Coat: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT | 8.0–12.0 mils DFT (excludes spot-prime coats) |
Moderate Duty, Solvent Based Epoxy w/ Urethane Finish S2.3 | Previously painted exposed steel, stairs, railings and equipment in visible interior spaces needing color and gloss retention | Wash clean; SSPC-SP2/SP3 Hand/Power Tool Cleaning to degloss; remove loose coatings; feather transition edges | Spot Prime: Series 135 Chembuild — 4.0–6.0 mils DFT First Coat: Series 135 Chembuild — 4.0–6.0 mils DFT Finish Coat: Series 1095 Endura-Shield — 3.0–4.0 mils DFT Note: Use Series 1090 as the finish coat for high traffic areas | 7.0–10.0 mils DFT (excludes spot-prime coats) |
Heavy Duty, Chemical Resistant Epoxy S2.4 | Previously painted steel in chemical rooms, laboratories, wash bays and process areas subject to chemical splash or washdown (non-immersion) | Wash clean; SSPC-SP2/SP3 Hand/Power Tool Cleaning; SSPC-SP11 to bare metal at corroded areas; feather transition edges | Touch-Up Primer: Series 1 Omnithane — 2.5–3.5 mils DFT First Coat: Series 104 H.S. Epoxy — 4.0–6.0 mils DFT Finish Coat: Series 104 H.S. Epoxy — 4.0–6.0 mils DFT | 8.0–12.0 mils DFT (excludes touch-up coats) |
Overhead Structural Steel / Joists / Deck, Dry-Fall S2.5 | Previously painted overhead structural steel, joists, deck, ductwork and conduit in open-ceiling spaces (dry-fall application) | Wash clean; SSPC-SP2/SP3 Hand/Power Tool Cleaning to degloss; remove loose coatings; feather transition edges | Spot Prime: Series 135 Chembuild — 4.0–6.0 mils DFT First Coat: Series 115 Uni-Bond DF — 2.0–4.0 mils DFT Finish Coat: Series 115 Uni-Bond DF — 2.0–4.0 mils DFT | 8.0–14.0 mils DFT |
Galvanized Steel, Epoxy Finish S2.6 | Galvanized pipe, handrails, ladders and miscellaneous fabrications — interior, non-immersion service | SSPC-SP1; SSPC-SP2/SP3 to degloss and remove loose coating; SSPC-SP16 at exposed galvanizing | First Coat: Series V69 Hi-Build Epoxoline II — 3.0–4.0 mils DFT Finish Coat: Series V69 Hi-Build Epoxoline II — 3.0–4.0 mils DFT | 6.0–8.0 mils DFT |
Galvanized Steel, Urethane Finish S2.7 | Previously painted galvanized railings, stairs, ladders, frames and miscellaneous fabrications in visible interior spaces needing color and gloss retention | SSPC-SP1; SSPC-SP2/SP3 to degloss and remove loose coating; SSPC-SP16 at exposed galvanizing | First Coat: Series V69 Hi-Build Epoxoline II — 3.0–4.0 mils DFT Finish Coat: Series 1095 Endura-Shield — 3.0–4.0 mils DFT | 6.0–8.0 mils DFT |
Hollow Metal Doors, Frames, Railings — Light Architectural Duty S2.8 | Previously painted hollow metal doors, frames, railings and trim in offices, corridors, classrooms and other low-abuse interior spaces | Wash clean; SSPC-SP2/SP3 Hand/Power Tool Cleaning to degloss; remove loose coatings; feather transition edges | Primer: Series 1028/1029 Enduratone — 2.0–3.0 mils DFT Finish Coat: Series 1028/1029 Enduratone — 2.0–3.0 mils DFT | 4.0–6.0 mils DFT |
Hollow Metal Doors, Frames, Railings — Moderate/Heavy Duty S2.9 | Lobbies, atriums, public areas, assembly spaces, garages, maintenance areas, exposed columns/beams and existing mechanical or support steel | Wash clean; SSPC-SP2/SP3 Hand/Power Tool Cleaning to degloss; remove loose coatings; feather transition edges | Primer: Series 27 Typoxy — 3.0–4.0 mils DFT Finish Coat: Series 1090 Endura-Shield — 3.0–4.0 mils DFT | 6.0–8.0 mils DFT |
T1 — GLAZED TILE / GLAZED BLOCK | ||||
Light/Moderate Duty T1.1 | Restrooms, kitchens, break rooms, utility rooms and existing tile receiving decorative or light-duty coatings | Clean thoroughly (Simple Green/TSP or similar); uniformly scarify to remove glaze/sheen (test patch recommended) | Primer: Series 108 ProBond — 1.0–2.0 mils DFT First Coat: Series 1028 Enduratone — 2.0–3.0 mils DFT Finish Coat: Series 1028 Enduratone — 2.0–3.0 mils DFT | 5.0–8.0 mils DFT |
Moderate/Heavy Duty, Epoxy w/ Urethane Finish T1.2 | Locker rooms, laboratories, commercial kitchens, service areas and tile requiring enhanced chemical, cleaning or abrasion resistance | Clean thoroughly (Simple Green/TSP or similar); uniformly scarify to remove glaze/sheen (test patch recommended) | Primer: Series 108 ProBond — 1.0–2.0 mils DFT First Coat: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT Finish Coat: Series 297 Enviro-Glaze — 2.0–3.0 mils DFT | 7.0–11.0 mils DFT |
Shower / Wet Walls T1.3 | Showers, locker rooms, wash areas and tiled wet rooms | Clean thoroughly (Simple Green/TSP or similar); uniformly scarify to remove glaze/sheen (test patch recommended) | Primer: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT First Coat: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT Finish Coat: Series 297 Enviro-Glaze — 2.0–3.0 mils DFT | 10.0–15.0 mils DFT |
M1 — MISCELLANEOUS INTERIOR SUBSTRATES | ||||
Wood — Bare or Previously Painted M1.1 | Doors, trim, millwork, paneling and exposed architectural wood | Clean and dry; sand smooth; remove loose/peeling paint and feather edges | Primer: Series V10 Tnemec Primer — 2.0–3.5 mils DFT First Coat: Series 1028/1029 Enduratone — 2.0–3.0 mils DFT Finish Coat: Series 1028/1029 Enduratone — 2.0–3.0 mils DFT | 6.0–9.5 mils DFT |
PVC Pipe, Trim and Plastic Components M1.2 | PVC trim, piping, panels and miscellaneous plastic components requiring field coating | Solvent clean and dry; lightly sand with #150-200 sandpaper | First Coat: Series 1028/1029 Enduratone — 2.0–3.0 mils DFT Finish Coat: Series 1028/1029 Enduratone — 2.0–3.0 mils DFT | 4.0–6.0 mils DFT |
Insulated Pipe Jacketing (Canvas / PVC Jacket) M1.3 | Canvas or PVC insulated pipe jacketing in mechanical rooms, boiler rooms, corridors and other exposed interior areas | Clean and dry | First Coat: Series 1026 Enduratone — 2.0–3.0 mils DFT Finish Coat: Series 1026 Enduratone — 2.0–3.0 mils DFT | 4.0–6.0 mils DFT |
Interior Aluminum and Non-Ferrous Metal M1.4 | Interior aluminum and non-ferrous railings, trim, frames, louvers, grilles and miscellaneous metal components | SSPC-SP1; light abrasive sweep blast or uniformly sand to profile; avoid damaging/warping thin components | Primer: Series 116 Uni-Bond — 2.0–4.0 mils DFT Finish Coat: Series 1028/1029 Enduratone — 2.0–3.0 mils DFT | 4.0–7.0 mils DFT |
EXTERIOR SYSTEMS | ||||
EC1 — NEW OR PREVIOUSLY UNCOATED CMU AND CONCRETE | ||||
Elastomeric / Crack-Bridging, Smooth Finish EC1.1 | Exterior masonry/CMU, unpainted | SSPC-SP13/NACE No. 6; clean, dry, free of oil/grease/form-release agents; allow new concrete/CMU to cure min. 14 days; repair cracks per mfr procedure | Block Filler (CMU, as needed): Series 130 Envirofill — 60–80 SF/gal Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT First Coat: Series 156 Enviro-Crete — 6.0–8.0 mils DFT Finish Coat: Series 156 Enviro-Crete — 6.0–8.0 mils DFT | 12.7–17.5 mils DFT (over block filler applied at coverage rate) |
Elastomeric / Crack-Bridging, Sand Textured Finish EC1.2 | Exterior CMU and concrete walls, screen walls and building envelopes where a sand-textured elastomeric finish is desired to hide surface irregularities | SSPC-SP13/NACE No. 6; clean, dry, free of oil/grease/form-release agents; allow new concrete/CMU to cure min. 14 days; repair cracks per mfr procedure | Block Filler (CMU, as needed): Series 130 Envirofill — 60–80 SF/gal Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT First Coat: Series 156 Enviro-Crete — 6.0–8.0 mils DFT Finish Coat: Series 157 Enviro-Crete (sand textured) — 6.0–9.0 mils DFT | 12.7–18.5 mils DFT (over block filler applied at coverage rate) |
EC2 — EXISTING / PREVIOUSLY PAINTED CMU, BRICK AND CONCRETE | ||||
Elastomeric / Crack-Bridging Recoat EC2.1 | Building envelopes, exterior CMU/concrete walls, above-grade foundations, screen walls, retaining walls and masonry requiring crack-bridging or weatherproofing | Power wash; remove loose/peeling coating and chalk; clean and dry | Primer (as needed): Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT First Coat: Series 156 Enviro-Crete — 4.0–6.0 mils DFT Finish Coat: Series 156 Enviro-Crete — 4.0–6.0 mils DFT | 8.0–12.0 mils DFT; optional Primer (as needed) 0.7–1.5 |
EC3 — STUCCO AND CEMENT PLASTER | ||||
Uncoated or Previously Painted EC3.1 | Exterior stucco and cement plaster walls, soffits, parapets and building envelope surfaces | SSPC-SP13 Surface Preparation of Concrete; clean and dry | Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT First Coat: Series 156 Enviro-Crete — 4.0–6.0 mils DFT Finish Coat: Series 156 Enviro-Crete — 4.0–6.0 mils DFT | 8.7–13.5 mils DFT |
ES1 — NEW OR FULL-COATING-REMOVAL STEEL | ||||
Zinc / Epoxy / Urethane (Good) ES1.1 | New fabrication or full coating removal — exterior structural steel, tanks, pipe supports and equipment, non-immersion service | SSPC-SP6/NACE No. 3 Commercial Blast Cleaning | Shop or Field Primer: Series 90-97 Tneme-Zinc — 2.5–3.5 mils DFT Touch-Up Primer: Series 90G-1K97 Tneme-Zinc — 2.5–3.5 mils DFT Intermediate: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT Finish Coat: Series 1095 Endura-Shield — 3.0–4.0 mils DFT Note: Use Series 1090 as the finish coat for high traffic areas | 9.5–13.5 mils DFT (excludes touch-up coats) |
Zinc / Epoxy / Urethane / Fluoropolymer (Best — Extended UV & Color Retention) ES1.2 | Architecturally exposed exterior steel — canopies, entrance structures, pedestrian bridges, light poles, sign structures and tank exteriors where extended color and gloss retention is required | SSPC-SP6/NACE No. 3 Commercial Blast Cleaning | Shop or Field Primer: Series 90-97 Tneme-Zinc — 2.5–3.5 mils DFT Touch-Up Primer: Series 90G-1K97 Tneme-Zinc — 2.5–3.5 mils DFT Stripe / Intermediate 1: Series V69 Hi-Build Epoxoline II — 3.0–5.0 mils DFT Intermediate 2: Series 1095 or 1096 Endura-Shield — 3.0–4.0 mils DFT Finish Coat: Series 1070/1071/1072 Fluoronar — 2.0–3.0 mils DFT | 10.5–15.5 mils DFT (excludes stripe/touch-up coats) |
ES2 — EXISTING / PREVIOUSLY PAINTED STEEL (OVERCOAT) | ||||
Epoxy Mastic / Urethane (Good) ES2.1 | Existing exterior steel with a sound coating — support steel, equipment, enclosures, fencing, gates, tank exteriors and miscellaneous steel receiving an overcoat | SSPC-SP2/SP3 Hand/Power Tool Cleaning; remove loose coating; feather transition edges | Spot Prime: Series 135 Chembuild — 4.0–6.0 mils DFT Full Prime Coat: Series 135 Chembuild — 4.0–6.0 mils DFT Finish Coat: Series 1095 Endura-Shield — 3.0–4.0 mils DFT Note: Use Series 1090 as the finish coat for high traffic areas | 7.0–10.0 mils DFT (excludes spot-prime coats) |
Epoxy Mastic / Urethane / Fluoropolymer (Best) ES2.2 | Existing canopies, entrance structures, bridges, support steel, light poles, sign frames, equipment screens and miscellaneous exposed steel where the existing coating remains | SSPC-SP2/SP3 Hand/Power Tool Cleaning; remove loose coating; feather transition edges | Spot Prime: Series 135 Chembuild — 4.0–6.0 mils DFT Full Prime Coat: Series 135 Chembuild — 4.0–6.0 mils DFT Intermediate: Series 1095 or 1096 Endura-Shield — 3.0–4.0 mils DFT Finish Coat: Series 1070/1071/1072 Fluoronar — 2.0–3.0 mils DFT | 9.0–13.0 mils DFT (excludes spot-prime coats) |
ES3 — GALVANIZED STEEL | ||||
New or Full Coating Removal, Urethane Finish (Good) ES3.1 | Exterior galvanized railings, stairs, ladders, canopies, fencing, gates, support steel and miscellaneous galvanized fabrications | SSPC-SP1 to remove oil/grease/contaminants; SSPC-SP16 to remove storage stains and uniformly profile | Primer: Series V69 Hi-Build Epoxoline II — 3.0–4.0 mils DFT Finish Coat: Series 1095 Endura-Shield — 3.0–4.0 mils DFT | 6.0–8.0 mils DFT |
New or Full Coating Removal, Fluoropolymer Finish (Best) ES3.2 | Exterior stairs, guards, handrails, canopies, structural supports, sign frames and galvanized assets requiring full refurbishment | Remove existing coating; abrasive blast per SSPC-SP16, min. 1.5-mil angular anchor profile | Spot Primer (repair damaged galvanizing): Series 94-H2O Hydro-Zinc — 2.5–3.5 mils DFT Primer: Series V69 Hi-Build Epoxoline II — 3.0–4.0 mils DFT Intermediate: Series 1095 or 1096 Endura-Shield — 2.0–3.0 mils DFT Finish Coat: Series 1070/1071/1072 Fluoronar — 2.0–3.0 mils DFT | 7.0–10.0 mils DFT (excludes spot-prime coats) |
Previously Coated Galvanized, Overcoat ES3.3 | Previously coated exterior galvanized railings, ladders, doors and frames, fencing, gates, support poles and miscellaneous galvanized metal | Wash clean; SSPC-SP2/SP3 Hand/Power Tool Cleaning to degloss; remove loose coatings; feather transition edges | Spot / Prime Coat: Series 27 Typoxy — 3.0–4.0 mils DFT Finish Coat: Series 1095 Endura-Shield — 3.0–4.0 mils DFT Optional Finish: Series 1070V Fluoronar — 2.0–3.0 mils DFT | 6.0–8.0 mils DFT; Optional Finish 2.0–3.0 |
ES4 — ALUMINUM AND NON-FERROUS METAL | ||||
General ES4.1 | Louvers, screens, railings, architectural trim, frames, stairs/platforms and exposed aluminum components | Light abrasive sweep blast (SSPC-SP16), uniform angular profile 1.0-2.0 mils; avoid damaging/warping thin components | Primer: Series V69 Hi-Build Epoxoline II — 2.0–3.0 mils DFT Intermediate: Series 1095 Endura-Shield — 2.0–3.0 mils DFT Finish Coat: Series 1071 Fluoronar — 2.0–3.0 mils DFT | 6.0–9.0 mils DFT |
ES5 — HOLLOW METAL DOORS AND FRAMES | ||||
Hollow Metal Doors, Frames, Railings — Light Architectural Duty ES5.1 | Exterior hollow metal doors, frames, railings and trim at entrances, service doors and other light-duty exterior locations | SSPC-SP1; SSPC-SP2/SP3 to degloss and remove loose coating; feather transition edges | Primer: Series 1028/1029 Enduratone — 2.0–3.0 mils DFT Finish Coat: Series 1028/1029 Enduratone — 2.0–3.0 mils DFT | 4.0–6.0 mils DFT |
Hollow Metal Doors, Frames, Railings — Moderate/Heavy Duty ES5.2 | Hollow-metal doors, frames, access doors, service doors, overhead-door components and similar ferrous assemblies | SSPC-SP1; SSPC-SP2/SP3 to degloss and remove loose coating; feather transition edges | Primer: Series 27 Typoxy — 3.0–4.0 mils DFT Finish Coat: Series 1095 Endura-Shield — 3.0–4.0 mils DFT Note: Use Series 1090 as the finish coat for high traffic areas | 6.0–8.0 mils DFT |
ES6 — METAL PANEL ROOFS AND WALLS (PREFINISHED / KYNAR) | ||||
Best — 15-Year Color and Gloss ES6.1 | Metal roof panels, wall panels, prefinished siding, fascias, copings and weathered factory-finished metal surfaces | Power wash clean in accordance with SSPC-SP1; uniformly scarify to remove glaze/sheen (test patch required) | Primer: Series 108 ProBond — 1.0–2.0 mils DFT Intermediate: Series 1095 Endura-Shield — 3.0–4.0 mils DFT Finish Coat: Series 1070V Fluoronar — 2.0–3.0 mils DFT | 6.0–9.0 mils DFT |
Good — 7-Year Color and Gloss ES6.2 | Metal roof panels, wall panels, prefinished siding, fascias and copings where a heat-reflective finish with a 7-year color and gloss warranty is acceptable | Power wash clean in accordance with SSPC-SP1; uniformly scarify to remove glaze/sheen (test patch required) | Primer: Tex-Cote Metal Prime — 1.0–2.0 mils DFT Intermediate: Tex-Cote Reflect-Tec — 3.0–4.0 mils DFT Finish Coat: Tex-Cote Reflect-Tec — 3.0–4.0 mils DFT | 7.0–10.0 mils DFT |
EW1 — WOOD | ||||
Bare or Previously Painted EW1.1 | Doors, trim, millwork, paneling and exposed architectural wood | Clean and dry; sand smooth | Primer: Series V10 Tnemec Primer — 2.0–3.5 mils DFT First Coat: Series 1028 Enduratone — 2.0–3.0 mils DFT Finish Coat: Series 1028 Enduratone — 2.0–3.0 mils DFT | 6.0–9.5 mils DFT |
ED1 — PEDESTRIAN DECK COATINGS (NON-VEHICULAR) | ||||
General Waterproofing, Broadcast ED1.1 | Walkways, balconies, plaza decks, breezeways, terraces and non-vehicular concrete decks requiring waterproofing and slip resistance | SSPC-SP13 Surface Preparation of Concrete | Primer: Series 154 TnemeGuard (thinned) — 4.0–7.0 mils DFT Slurry / Broadcast Coat: Series 154 TnemeGuard with 30/50 silica sand — 10.0–14.0 mils DFT Optional Grout Coat: Series 154 TnemeGuard — 10.0–14.0 mils DFT Finish Coat: Series 297 Enviro-Glaze — 2.0–3.0 mils DFT | 16.0–24.0 mils DFT; Optional Grout Coat 10.0–14.0 |
Exposed Concrete Stairs and Elevated Decks, Mesh-Reinforced ED1.2 | Exterior or exposed concrete stairs, landings, ramps, platforms and elevated decks requiring a mesh-reinforced, slip-resistant walking surface | Wash clean; prepare concrete by sanding, light grinding, or pressurized water cleaning at 4,000-5,000 psi w/ zero-degree oscillating tip; clean, dry, sound. Fill hairline cracks (<1/64") by brushing Series 154 in; cracks ≥1/64" or moving cracks/joints — reinforce w/ Series S211 woven mesh. | Steel Spot Prime (as applicable): Series 118 Uni-Bond Mastic — 4.0–6.0 mils DFT Primer: Series 154 TnemeGuard (thinned) — 4.0–7.0 mils DFT 1st Intermediate: Series 154 TnemeGuard with S211 woven mesh — 10.0–14.0 mils DFT 2nd Intermediate: Series 154 TnemeGuard with silica sand broadcast — 10.0–14.0 mils DFT Finish Coat: Series 297 Enviro-Glaze — 2.0–3.0 mils DFT | 26.0–38.0 mils DFT (excludes spot-prime coats) |
ESL1 — WATER REPELLENTS, SEALERS AND ANTI-GRAFFITI | ||||
Penetrating Silane/Siloxane Water Repellent ESL1.1 | Exterior concrete, precast, brick, block, stone, stucco and other absorptive masonry exposed to weather; clear penetrating water repellent with no film build | Per product surface-absorption test; clean, dry, free of efflorescence | Sealer: Series 633 Prime-A-Pell H2O (Tnemec) — or Tex-Cote Rainstopper 120/140 — N/A (penetrating sealer) | Not applicable — penetrating sealer, no measurable dry film thickness |
Anti-Graffiti (Sacrificial / Non-Sacrificial) ESL1.2 | Exterior masonry, concrete and coated walls at grade level, entrances, underpasses and other areas subject to graffiti | Clean and dry; if previously coated, uniformly scarify to sound coating | Primer (porous masonry only): Rainstopper 1750W Clear Sealer (TEX-COTE) — Applied at coverage rate Topcoat: Graffiti Gard IV (TEX-COTE) — 250–350 SF/gal clear; 150–200 SF/gal pigmented | Not specified — system applied by coverage rate; see coat schedule |
SPECIALTY SYSTEMS | ||||
X1 — SPECIALTY SYSTEMS | ||||
Aerogel Thermal-Break Coating at Steel Envelope Penetrations X1.1 | Steel penetrating the building envelope — relieving angles, lintels, canopy and balcony steel and other thermal-bridge locations | SSPC-SP6/NACE No. 3 Commercial Blast Cleaning | Primer: Series 394 PerimePrime — 2.5–3.5 mils DFT Insulative Coating (2–3 coats by shape): Series 971 Aerolon — 40.0–50.0 per coat (2 coats W-shapes / 3 coats HSS & deck) Finish (exposed to view): Series 1028 Enduratone — 2.0–3.0 mils DFT | 80–150 mils DFT (per shape; 2 coats W-shapes, 3 coats HSS/deck) plus 2.0–3.0 finish where exposed |
Where to Go Next
For CSI 3-part bid/construction specification language built from these same systems, use Section 09 96 00, High-Performance Coatings, or contact Atlantic Coating Consultants for a project-specific specification.
For resinous flooring, use the companion Short-Form System Reference Guide — Resinous Flooring and Section 09 67 23. For process-facility applications, use the companion Water Treatment and Wastewater Treatment Short-Form System Reference guides.
For pool/aquatic linings, secondary containment, potable-water or wastewater immersion systems, or specialty exposures not covered here, contact Atlantic Coating Consultants.
Prepared as a service by: Atlantic Coating Consultants | Wally Bates | atlantic@tnemec.com | 484-644-5303