top of page

Short-Form System Reference Guide: Architectural Interior and Exterior Coatings

Wally Bates
Sep 27
25 min read

Use this guide to choose a coating system by substrate, exposure and service condition. It is a selection reference, not a bid-ready specification. The full guide is below, and a PDF copy is free to download.

Download the PDF: the file is attached at the end of this page.

For bid documents: use the companion Section 09 96 00 High-Performance Coatings guide specification, or ask ACC for a specification tailored to your project.

Questions: atlantic@tnemec.com or 484-644-5303.


Reader's Note

Use this guide to quickly select an architectural coating system by substrate, exposure, and service condition. It is a selection reference for architects, engineers, facilities/asset managers, and project teams; it is not a bid-ready specification.

For bid or construction documents, use the companion CSI 3-part specification, Section 09 96 00 - High-Performance Coatings, or contact ACC for project-specific guidance.

Prepared as a service by: Atlantic Coating Consultants | Wally Bates | atlantic@tnemec.com | 484-644-5303

Overview

1. Purpose

This guide summarizes commonly used architectural interior and exterior coating systems for concrete/CMU, structural and miscellaneous metals, concrete ceilings, glazed tile, wood, PVC, stucco, metal panels, doors/frames, pedestrian decks, sealers and related building surfaces. Systems are organized by substrate and exposure so they can be used across institutional, municipal, commercial, and similar facilities.

2. How to Use This Guide

• Start with the Quick Locator Index if you know the substrate or building component. Find the applicable system in the schedule below.

• If you know the substrate and exposure, go directly to the system tables and match the Condition and Typical Locations.

• Use Surface Preparation, Coat Schedule, and Total Build for budgeting, work-order planning, and contractor pricing.

• Contact ACC to confirm project-specific exposure, existing coating condition, color/gloss, aesthetics, or full CSI specification requirements.

3. Basis of Design

Products scheduled herein are manufactured by Tnemec Company, Inc. (with select exterior metal-panel-roof and water-repellent systems by Tex-Cote LLC, noted where used) and are listed as the basis of design for the performance, appearance, and warranty characteristics described.

4. Not Covered in This Guide

Typical Locations are intentionally broad so the guide can be used across building types. Resinous flooring systems are in the companion Short-Form System Reference Guide — Resinous Flooring. Facility-specific process systems are maintained in the separate ACC water and wastewater references.

5. General Application & Warranty Notes

• Follow the current manufacturer product data sheet for substrate, ambient, dew-point, humidity, ventilation, surface-profile, and application requirements.

• Verify dry film thickness during and after application. For decorative, reinforced, or resinous systems, consider a mock-up or field sample before full-scale application.

• Concrete/CMU surface-profile requirements vary by system; confirm the specified ICRI CSP and verify surface preparation before full-scale work.

• Confirm optional topcoats, alternate finishes, color, and gloss selections with the Owner/Architect before ordering or application.

• Warranty terms vary by system and project; contact ACC or the manufacturer to confirm applicable coverage, including exterior metal-panel color/gloss warranty options.

Quick Locator Index

Find a system by substrate or building component. Confirm project-specific conditions before final selection.

System Group

Applicable System

INTERIOR SYSTEMS


CMU / CONCRETE WALLS

New or Uncoated CMU — Light Architectural Duty


New or Uncoated CMU — Moderate Duty, Water Based


New or Uncoated CMU — Moderate Duty, Solvent Based


New or Uncoated CMU — Moderate/Heavy Duty, Water Based w/ Urethane Finish


New or Uncoated CMU — Moderate/Heavy Duty, 100% Solids Epoxy w/ Urethane Finish


New or Uncoated CMU — Moderate/Heavy Duty, Chemical Resistant


New or Uncoated CMU — Heavy Duty / Washdown, 100% Solids Reinforced


New or Uncoated Concrete — Light Duty


New or Uncoated Concrete — Moderate Duty, Water Based


New or Uncoated Concrete — Moderate Duty, Solvent Based


New or Uncoated Concrete — Moderate/Heavy Duty, Water Based w/ Urethane Finish


New or Uncoated Concrete — Moderate/Heavy Duty, 100% Solids Epoxy w/ Urethane Finish


New or Uncoated Concrete — Moderate/Heavy Duty, Chemical Resistant


Previously Painted CMU/Concrete — Light Duty


Previously Painted CMU/Concrete — Moderate Duty, Water Based


Previously Painted CMU/Concrete — Moderate Duty, Solvent Based


Previously Painted CMU/Concrete — Moderate/Heavy Duty, Water Based w/ Urethane Finish


Previously Painted CMU/Concrete — Moderate/Heavy Duty, 100% Solids Epoxy w/ Urethane Finish


Previously Painted CMU/Concrete — Moderate/Heavy Duty, Chemical Resistant

STRUCTURAL STEEL

New or Uncoated Steel — Moderate Duty, Solvent Based Epoxy


New or Uncoated Steel — Moderate Duty, Solvent Based Epoxy w/ Urethane Finish


New or Uncoated Steel — Heavy Duty, Chemical Resistant Epoxy


New or Uncoated Steel — Overhead Structural Steel / Joists / Deck, Dry-Fall


Previously Painted Steel — Moderate Duty, Solvent Based Epoxy Finish


Previously Painted Steel — Moderate Duty, Solvent Based Epoxy w/ Urethane Finish


Previously Painted Steel — Heavy Duty, Chemical Resistant Epoxy


Previously Painted Steel — Overhead Structural Steel / Joists / Deck, Dry-Fall

STEEL RAILINGS & HANDRAILS

New or Uncoated Steel — Light Architectural Duty


Previously Painted Steel — Light Architectural Duty


Previously Painted Steel — Hollow Metal Doors, Frames, Railings — Light Architectural Duty


Previously Painted Steel — Hollow Metal Doors, Frames, Railings — Moderate/Heavy Duty

GALVANIZED STEEL & ALUMINUM — INTERIOR

New or Uncoated Steel — Galvanized Steel, Epoxy Finish


New or Uncoated Steel — Galvanized Steel, Urethane Finish


New or Uncoated Steel — Galvanized Steel, Light Architectural Duty


Previously Painted Steel — Galvanized Steel, Epoxy Finish


Previously Painted Steel — Galvanized Steel, Urethane Finish


Interior Aluminum and Non-Ferrous Metal

CONCRETE PLANK CEILINGS

Dry-Fall, High-Moisture / Natatorium Ceilings


Flexible / Mildew-Resistant Ceilings (Locker Rooms)

GYPSUM BOARD

Gypsum board systems are not covered in this guide; contact ACC for a project-specific recommendation.

GLAZED TILE

Light/Moderate Duty


Moderate/Heavy Duty, Epoxy w/ Urethane Finish


Shower / Wet Walls

WOOD (BARE OR PREVIOUSLY PAINTED)

Wood — Bare or Previously Painted

PVC

PVC Pipe, Trim and Plastic Components


Insulated Pipe Jacketing (Canvas / PVC Jacket)

EXTERIOR SYSTEMS


STRUCTURAL / ARCHITECTURALLY EXPOSED STEEL

New or Full Coating Removal — Zinc / Epoxy / Urethane (Good)


New or Full Coating Removal — Zinc / Epoxy / Urethane / Fluoropolymer (Best — Extended UV & Color Retention)


Overcoat — Epoxy Mastic / Urethane (Good)


Overcoat — Epoxy Mastic / Urethane / Fluoropolymer (Best)

STEEL RAILINGS — EXTERIOR

New or Full Coating Removal — Zinc / Epoxy / Urethane (Good)


New or Full Coating Removal — Zinc / Epoxy / Urethane / Fluoropolymer (Best — Extended UV & Color Retention)


Hollow Metal Doors, Frames, Railings — Light Architectural Duty


Hollow Metal Doors, Frames, Railings — Moderate/Heavy Duty

System Group

Applicable System — Click to Jump

GALVANIZED STEEL — EXTERIOR

New or Full Coating Removal, Urethane Finish (Good)


New or Full Coating Removal, Fluoropolymer Finish (Best)


Previously Coated Galvanized, Overcoat

ALUMINUM — EXTERIOR

General

CMU / CONCRETE WALLS — ELASTOMERIC / CRACK-BRIDGING

Uncoated — Elastomeric / Crack-Bridging, Smooth Finish


Uncoated — Elastomeric / Crack-Bridging, Sand Textured Finish


Previously Painted — Elastomeric / Crack-Bridging Recoat

CMU / CONCRETE WALLS — BREATHABLE COATING SYSTEM

Uncoated — Series 156 Enviro-Crete, Smooth Finish


Uncoated — Series 156/157 Enviro-Crete, Sand Textured Finish


Previously Painted — Series 156 Enviro-Crete Recoat


Stucco — Series 156 Enviro-Crete

STUCCO

Uncoated or Previously Painted

WOOD — EXTERIOR

Bare or Previously Painted

METAL PANEL ROOFS & WALLS — BEST (15-YEAR COLOR & GLOSS WARRANTY)

Best — 15-Year Color and Gloss

METAL PANEL ROOFS & WALLS — GOOD (7-YEAR COLOR & GLOSS WARRANTY)

Good — 7-Year Color and Gloss

HOLLOW METAL DOORS AND FRAMES — EXTERIOR

Hollow Metal Doors, Frames, Railings — Light Architectural Duty


Hollow Metal Doors, Frames, Railings — Moderate/Heavy Duty

PEDESTRIAN DECK COATING (NON-VEHICULAR)

General Waterproofing, Broadcast


Exposed Concrete Stairs and Elevated Decks, Mesh-Reinforced

WATER REPELLENTS & SEALERS

Penetrating Silane/Siloxane Water Repellent


Anti-Graffiti (Sacrificial / Non-Sacrificial)

RESINOUS FLOORING


EPOXY BROADCAST SYSTEMS

Epoxy broadcast floor systems (100% solids and water-based) are in the companion Short-Form System Reference Guide — Resinous Flooring (Section 09 67 23).

URETHANE CEMENT SYSTEMS

Urethane cement floor systems are in the companion Short-Form System Reference Guide — Resinous Flooring (Section 09 67 23).

REINFORCED WATERPROOF DECK COATING

The reinforced waterproof deck coating is in the companion Short-Form System Reference Guide — Resinous Flooring (Section 09 67 23).

SPECIALTY SYSTEMS


THERMAL-BREAK COATINGS

Aerogel Thermal-Break Coating at Steel Envelope Penetrations

Architectural Interior & Exterior Coating Systems

Includes interior systems for CMU, concrete, ceilings, steel, galvanized and non-ferrous metal, glazed tile, wood and PVC; exterior systems for masonry, stucco, steel, galvanized, aluminum, doors and frames, metal panels, wood, pedestrian decks and sealers; and specialty systems. Based on Section 09 96 00.

Condition

Typical Locations

Surface Preparation

Coat Schedule (Product — DFT)

Total Build

INTERIOR SYSTEMS





C1 — NEW OR PREVIOUSLY UNCOATED CMU





Light Architectural Duty


C1.1

Offices, corridors, classrooms, conference rooms, storage and other low-abuse interior block walls receiving a breathable acrylic finish

Clean and dry; allow new CMU and mortar to cure a minimum of 28 days; remove efflorescence, loose mortar and dust

Block Filler: Series 130 Envirofill — 60–80 SF/gal


First Coat: Series 1026 Enduratone — 2.0–3.0 mils DFT


Finish Coat: Series 1026 Enduratone — 2.0–3.0 mils DFT

4.0–6.0 mils DFT (over block filler applied at coverage rate)

Moderate Duty, Water Based


C1.2

Storage rooms, mechanical/electrical rooms, utility rooms, workshops, service areas and general-use uncoated block walls

Clean and dry; allow new CMU and mortar to cure a minimum of 28 days; remove efflorescence, loose mortar and dust

Block Filler: Series 130 Envirofill — 60–80 SF/gal


First Coat: Series 288/289 Enviro-Pox — 4.0–6.0 mils DFT


Finish Coat: Series 288/289 Enviro-Pox — 4.0–6.0 mils DFT

8.0–12.0 mils DFT (over block filler applied at coverage rate)

Moderate Duty, Solvent Based


C1.3

Mechanical/electrical rooms, workshops, garages, storage and service areas where a solvent-based epoxy finish is acceptable and low odor is not required

Clean and dry; allow new CMU and mortar to cure a minimum of 28 days; remove efflorescence, loose mortar and dust

Block Filler: Series 130 Envirofill — 60–80 SF/gal


First Coat: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT


Finish Coat: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT

8.0–12.0 mils DFT (over block filler applied at coverage rate)

Moderate/Heavy Duty, Water Based w/ Urethane Finish


C1.4

Locker rooms, restrooms, kitchens, corridors, custodial and service areas needing a scrubbable, color-retentive urethane finish over low-odor epoxy

Clean and dry; allow new CMU and mortar to cure a minimum of 28 days; remove efflorescence, loose mortar and dust

Block Filler: Series 130 Envirofill — 60–80 SF/gal


First Coat: Series 288/289 Enviro-Pox — 4.0–6.0 mils DFT


Finish Coat: Series 297 Enviro-Glaze — 2.0–3.0 mils DFT

6.0–9.0 mils DFT (over block filler applied at coverage rate)

Moderate/Heavy Duty, 100% Solids Epoxy w/ Urethane Finish


C1.5

Laboratories, kitchens, washdown rooms, corridors and high-abuse areas where a 100% solids epoxy build and urethane finish are required

Clean and dry; allow new CMU and mortar to cure a minimum of 28 days; remove efflorescence, loose mortar and dust

Block Filler: Series 1254 Epoxoblock WB — ~100 SF/gal (CMU)


First Coat: Series 280 Tneme-Glaze — 4.0–6.0 mils DFT


Finish Coat: Series 297 Enviro-Glaze — 2.0–3.0 mils DFT

6.0–9.0 mils DFT (over block filler applied at coverage rate)

Moderate/Heavy Duty, Chemical Resistant


C1.6

Chemical storage and feed rooms (non-immersion), laboratories, battery rooms, wash bays and areas subject to chemical splash or frequent washdown

Clean and dry; allow new CMU and mortar to cure a minimum of 28 days; remove efflorescence, loose mortar and dust

Block Filler: Series 130 Envirofill — 60–80 SF/gal


First Coat: Series 104 H.S. Epoxy — 4.0–6.0 mils DFT


Finish Coat: Series 104 H.S. Epoxy — 4.0–6.0 mils DFT

8.0–12.0 mils DFT (over block filler applied at coverage rate)

Heavy Duty / Washdown, 100% Solids Reinforced


C1.7

High-traffic corridors, secure or controlled-access areas, maintenance/service spaces, wet areas, laboratories and walls subject to repeated impact or abuse

Clean and dry; allow new CMU and mortar to cure a minimum of 28 days; remove efflorescence, loose mortar and dust

Filler: Series 215 Surfacing Epoxy — 25–40 SF/gal


Glass Mat: Series 273 ML Stranlok, embedded into wet Series 215


Saturant: Series 280 Tneme-Glaze — 8.0–10.0 mils DFT


Intermediate: Series 280 Tneme-Glaze — 6.0–8.0 mils DFT


Finish Coat: Series 297 Enviro-Glaze — 2.0–3.0 mils DFT

16.0–21.0 mils DFT (over surfacer/filler applied as needed — not a rated coat)

C2 — NEW OR PREVIOUSLY UNCOATED CONCRETE





Light Duty


C2.1

Offices, corridors, storage and other low-abuse interior poured or precast concrete walls

SSPC-SP13/NACE No. 6 Surface Preparation of Concrete; ICRI-CSP 2-3; clean, dry, cured a minimum of 28 days

Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT


Filler (as needed): Series 215 Surfacing Epoxy — Applied at coverage rate


First Coat: Series 1026 Enduratone — 2.0–3.0 mils DFT


Finish Coat: Series 1026 Enduratone — 2.0–3.0 mils DFT

4.7–7.5 mils DFT (over surfacer/filler applied as needed — not a rated coat)

Moderate Duty, Water Based


C2.2

Basements, utility rooms, service corridors, mechanical rooms and general interior poured or precast concrete walls in occupied facilities

SSPC-SP13/NACE No. 6 Surface Preparation of Concrete; ICRI-CSP 2-3; clean, dry, cured a minimum of 28 days

Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT


Filler (as needed): Series 215 Surfacing Epoxy — Applied at coverage rate


First Coat: Series 288/289 Enviro-Pox — 4.0–6.0 mils DFT


Finish Coat: Series 288/289 Enviro-Pox — 4.0–6.0 mils DFT

8.7–13.5 mils DFT (over surfacer/filler applied as needed — not a rated coat)

Moderate Duty, Solvent Based


C2.3

Mechanical/electrical rooms, workshops, garages, service and process support areas with interior concrete walls where low odor is not required

SSPC-SP13/NACE No. 6 Surface Preparation of Concrete; ICRI-CSP 2-3; clean, dry, cured a minimum of 28 days

Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT


Filler (as needed): Series 215 Surfacing Epoxy — Applied at coverage rate


First Coat: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT


Finish Coat: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT

8.7–13.5 mils DFT (over surfacer/filler applied as needed — not a rated coat)

Moderate/Heavy Duty, Water Based w/ Urethane Finish


C2.4

Locker rooms, restrooms, kitchens, corridors and frequently cleaned interior concrete walls needing a urethane finish

SSPC-SP13/NACE No. 6 Surface Preparation of Concrete; ICRI-CSP 2-3; clean, dry, cured a minimum of 28 days

Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT


Filler (as needed): Series 215 Surfacing Epoxy — Applied at coverage rate


First Coat: Series 288/289 Enviro-Pox — 4.0–6.0 mils DFT


Finish Coat: Series 297 Enviro-Glaze — 2.0–3.0 mils DFT

6.7–10.5 mils DFT (over surfacer/filler applied as needed — not a rated coat)

Moderate/Heavy Duty, 100% Solids Epoxy w/ Urethane Finish


C2.5

Laboratories, washdown rooms, process support spaces and high-abuse interior concrete walls requiring a 100% solids epoxy build and urethane finish

SSPC-SP13/NACE No. 6 Surface Preparation of Concrete; ICRI-CSP 2-3; clean, dry, cured a minimum of 28 days

Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT


Filler (as needed): Series 215 Surfacing Epoxy — Applied at coverage rate


First Coat: Series 280 Tneme-Glaze — 4.0–6.0 mils DFT


Finish Coat: Series 297 Enviro-Glaze — 2.0–3.0 mils DFT

6.7–10.5 mils DFT (over surfacer/filler applied as needed — not a rated coat)

Moderate/Heavy Duty, Chemical Resistant


C2.6

Chemical rooms (non-immersion), laboratories, wash bays and interior concrete walls subject to chemical splash or frequent washdown

SSPC-SP13/NACE No. 6 Surface Preparation of Concrete; ICRI-CSP 2-3; clean, dry, cured a minimum of 28 days

Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT


Filler (as needed): Series 215 Surfacing Epoxy — Applied at coverage rate


First Coat: Series 104 H.S. Epoxy — 4.0–6.0 mils DFT


Finish Coat: Series 104 H.S. Epoxy — 4.0–6.0 mils DFT

8.7–13.5 mils DFT (over surfacer/filler applied as needed — not a rated coat)

C3 — EXISTING / PREVIOUSLY PAINTED CMU AND CONCRETE





Light Duty


C3.1

Previously painted offices, corridors, classrooms, storage and other low-abuse interior CMU or concrete walls

SSPC-SP1; remove chalk/loose paint, patch cracks, spot prime bare areas, dull glossy surfaces

Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT


Filler (as needed): Series 215 Surfacing Epoxy — Applied at coverage rate


First Coat: Series 1026 Enduratone — 2.0–3.0 mils DFT


Finish Coat: Series 1026 Enduratone — 2.0–3.0 mils DFT

4.7–7.5 mils DFT (over surfacer/filler applied as needed — not a rated coat)

Moderate Duty, Water Based


C3.2

Previously painted corridors, restrooms, break rooms, utility and service areas receiving a low-odor epoxy maintenance coating

SSPC-SP1; remove chalk/loose paint, patch cracks, spot prime bare areas, dull glossy surfaces

Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT


Filler (as needed): Series 215 Surfacing Epoxy — Applied at coverage rate


First Coat: Series 288/289 Enviro-Pox — 4.0–6.0 mils DFT


Finish Coat: Series 288/289 Enviro-Pox — 4.0–6.0 mils DFT

8.7–13.5 mils DFT (over surfacer/filler applied as needed — not a rated coat)

Moderate Duty, Solvent Based


C3.3

Previously painted mechanical rooms, workshops, garages and service areas where a solvent-based epoxy recoat is acceptable

SSPC-SP1; remove chalk/loose paint, patch cracks, spot prime bare areas, dull glossy surfaces

Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT


Filler (as needed): Series 215 Surfacing Epoxy — Applied at coverage rate


First Coat: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT


Finish Coat: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT

8.7–13.5 mils DFT (over surfacer/filler applied as needed — not a rated coat)

Moderate/Heavy Duty, Water Based w/ Urethane Finish


C3.4

Previously painted locker rooms, restrooms, kitchens, corridors and frequently cleaned walls needing a urethane finish

SSPC-SP1; remove chalk/loose paint, patch cracks, spot prime bare areas, dull glossy surfaces

Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT


Filler (as needed): Series 215 Surfacing Epoxy — Applied at coverage rate


First Coat: Series 288/289 Enviro-Pox — 4.0–6.0 mils DFT


Finish Coat: Series 297 Enviro-Glaze — 2.0–3.0 mils DFT

6.7–10.5 mils DFT (over surfacer/filler applied as needed — not a rated coat)

Moderate/Heavy Duty, 100% Solids Epoxy w/ Urethane Finish


C3.5

Previously painted laboratories, washdown rooms and high-abuse walls requiring a 100% solids epoxy build and urethane finish

SSPC-SP1; remove chalk/loose paint, patch cracks, spot prime bare areas, dull glossy surfaces

Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT


Filler (as needed): Series 215 Surfacing Epoxy — Applied at coverage rate


First Coat: Series 280 Tneme-Glaze — 4.0–6.0 mils DFT


Finish Coat: Series 297 Enviro-Glaze — 2.0–3.0 mils DFT

6.7–10.5 mils DFT (over surfacer/filler applied as needed — not a rated coat)

Moderate/Heavy Duty, Chemical Resistant


C3.6

Previously painted chemical rooms (non-immersion), laboratories, wash bays and walls subject to chemical splash or washdown

SSPC-SP1; remove chalk/loose paint, patch cracks, spot prime bare areas, dull glossy surfaces

Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT


Filler (as needed): Series 215 Surfacing Epoxy — Applied at coverage rate


First Coat: Series 104 H.S. Epoxy — 4.0–6.0 mils DFT


Finish Coat: Series 104 H.S. Epoxy — 4.0–6.0 mils DFT

8.7–13.5 mils DFT (over surfacer/filler applied as needed — not a rated coat)

C4 — CONCRETE CEILINGS – NEW, EXISTING PAINTED OR STRUCTURAL, PLANK AND DECK





Dry-Fall, High-Moisture / Natatorium Ceilings


C4.1

Pool or aquatic areas, high-humidity mechanical rooms, laundry areas, wash bays, wet-process rooms and persistently humid interior spaces

SSPC-SP13/NACE No. 6; clean and dry; remove loose/peeling coating on previously painted ceilings

Primer: Series 115 Uni-Bond DF — 2.0–4.0 mils DFT


Intermediate: Series 115 Uni-Bond DF — 2.0–4.0 mils DFT


Finish Coat: Series 115 Uni-Bond DF — 2.0–4.0 mils DFT

6.0–12.0 mils DFT

Flexible / Mildew-Resistant Ceilings (Locker Rooms)


C4.2

Locker rooms, showers, laundry rooms, restrooms, wash areas and intermittently humid interior spaces

SSPC-SP13/NACE No. 6; clean and dry; remove loose/peeling coating on previously painted ceilings

Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT


First Coat: Series 158 Bio-Lastic — 6.0–7.0 mils DFT


Finish Coat: Series 158 Bio-Lastic — 6.0–7.0 mils DFT

12.7–15.5 mils DFT

S1 — NEW OR PREVIOUSLY UNCOATED STEEL





Light Architectural Duty


S1.1

Doors and frames, railings, trim, miscellaneous metals and exposed steel in offices and other low-abuse interior spaces

SSPC-SP1 Solvent Cleaning; SSPC-SP2/SP3 Hand/Power Tool Cleaning minimum (SSPC-SP6 preferred)

Primer: Series V10 Tnemec Primer — 2.0–3.5 mils DFT


Touch-Up Primer: Series V10 Tnemec Primer — 2.0–3.5 mils DFT


First Coat: Series 1026 Enduratone — 2.0–3.0 mils DFT


Finish Coat: Series 1026 Enduratone — 2.0–3.0 mils DFT

6.0–9.5 mils DFT (excludes touch-up coats)

Moderate Duty, Solvent Based Epoxy


S1.2

Structural steel, columns, beams, equipment supports, platforms and miscellaneous steel in mechanical rooms, garages, shops and process support areas

SSPC-SP6/NACE No. 3 Commercial Blast Cleaning

Primer: Series 1 Omnithane — 2.5–3.5 mils DFT


Touch-Up Primer: Series 1 Omnithane — 2.5–3.5 mils DFT


First Coat: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT


Finish Coat: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT


Note: Specify Series 90-97 Tneme-Zinc for natatorium and/or wet environments.

10.5–15.5 mils DFT (excludes touch-up coats)

Moderate Duty, Solvent Based Epoxy w/ Urethane Finish


S1.3

Exposed structural steel, stairs, railings, mezzanines and equipment in lobbies, gymnasiums, corridors and other visible interior spaces needing color and gloss retention

SSPC-SP6/NACE No. 3 Commercial Blast Cleaning

Primer: Series 1 Omnithane — 2.5–3.5 mils DFT


Touch-Up Primer: Series 1 Omnithane — 2.5–3.5 mils DFT


First Coat: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT


Finish Coat: Series 1095 Endura-Shield — 3.0–4.0 mils DFT


Note: Specify Series 90-97 Tneme-Zinc for natatorium and/or wet environments.


Note: Use Series 1090 as the finish coat for high traffic areas

9.5–13.5 mils DFT (excludes touch-up coats)

Heavy Duty, Chemical Resistant Epoxy


S1.4

Steel in chemical rooms, laboratories, wash bays and process areas subject to chemical splash, fumes or frequent washdown (non-immersion)

SSPC-SP10/NACE No. 2 Near-White Metal Blast Cleaning

Primer: Series 1 Omnithane — 2.5–3.5 mils DFT


Touch-Up Primer: Series 1 Omnithane — 2.5–3.5 mils DFT


Stripe Coat: Series 104 H.S. Epoxy — 4.0–6.0 mils DFT


First Coat: Series 104 H.S. Epoxy — 4.0–6.0 mils DFT


Finish Coat: Series 104 H.S. Epoxy — 4.0–6.0 mils DFT

10.5–15.5 mils DFT (excludes stripe/touch-up coats)

Overhead Structural Steel / Joists / Deck, Dry-Fall


S1.5

Overhead structural steel, bar joists, metal deck, ductwork and conduit in gymnasiums, warehouses, shops and open-ceiling spaces (dry-fall application)

SSPC-SP6/NACE No. 3 Commercial Blast Cleaning

Primer: Series 1 Omnithane — 2.5–3.5 mils DFT


Touch-Up Primer: Series 1 Omnithane — 2.5–3.5 mils DFT


First Coat: Series 115 Uni-Bond DF — 2.0–4.0 mils DFT


Finish Coat: Series 115 Uni-Bond DF — 2.0–4.0 mils DFT


Note: Specify Series 90-97 Tneme-Zinc for natatorium and/or wet environments.

6.5–11.5 mils DFT (excludes touch-up coats)

Galvanized Steel, Epoxy Finish


S1.6

Galvanized pipe, handrails, ladders and miscellaneous fabrications — interior, non-immersion service

SSPC-SP1 to remove oil/grease/contaminants; SSPC-SP16 to remove storage stains and uniformly profile

First Coat: Series V69 Hi-Build Epoxoline II — 3.0–4.0 mils DFT


Finish Coat: Series V69 Hi-Build Epoxoline II — 3.0–4.0 mils DFT

6.0–8.0 mils DFT

Galvanized Steel, Urethane Finish


S1.7

Exposed galvanized railings, stairs, ladders, frames and miscellaneous fabrications in visible interior spaces needing color and gloss retention

SSPC-SP1 to remove oil/grease/contaminants; SSPC-SP16 to remove storage stains and uniformly profile

First Coat: Series V69 Hi-Build Epoxoline II — 3.0–4.0 mils DFT


Finish Coat: Series 1095 Endura-Shield — 3.0–4.0 mils DFT

6.0–8.0 mils DFT

Galvanized Steel, Light Architectural Duty


S1.8

Railings, stairs, ladders, supports, equipment frames, guards and miscellaneous galvanized or nonferrous metal

SSPC-SP1 to remove oil/grease/contaminants; SSPC-SP16 to remove storage stains and uniformly profile

Primer: Series 116 Uni-Bond — 2.0–4.0 mils DFT


Finish Coat: Series 1028 Enduratone — 2.0–3.0 mils DFT

4.0–7.0 mils DFT

S2 — EXISTING / PREVIOUSLY PAINTED STEEL





Light Architectural Duty


S2.1

Previously painted doors and frames, railings, trim and miscellaneous metals in low-abuse interior spaces

Wash clean; SSPC-SP2/SP3 Hand/Power Tool Cleaning to degloss; remove loose coatings; feather transition edges

Spot Primer: Series V10 Tnemec Primer — 2.0–3.5 mils DFT


First Coat: Series 1026 Enduratone — 2.0–3.0 mils DFT


Finish Coat: Series 1026 Enduratone — 2.0–3.0 mils DFT

6.0–9.5 mils DFT

Moderate Duty, Solvent Based Epoxy Finish


S2.2

Previously painted structural steel, equipment supports, platforms and miscellaneous steel in mechanical rooms, garages, shops and process support areas

Wash clean; SSPC-SP2/SP3 Hand/Power Tool Cleaning to degloss; remove loose coatings; feather transition edges

Spot Prime: Series 135 Chembuild — 4.0–6.0 mils DFT


First Coat: Series 135 Chembuild — 4.0–6.0 mils DFT


Finish Coat: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT

8.0–12.0 mils DFT (excludes spot-prime coats)

Moderate Duty, Solvent Based Epoxy w/ Urethane Finish


S2.3

Previously painted exposed steel, stairs, railings and equipment in visible interior spaces needing color and gloss retention

Wash clean; SSPC-SP2/SP3 Hand/Power Tool Cleaning to degloss; remove loose coatings; feather transition edges

Spot Prime: Series 135 Chembuild — 4.0–6.0 mils DFT


First Coat: Series 135 Chembuild — 4.0–6.0 mils DFT


Finish Coat: Series 1095 Endura-Shield — 3.0–4.0 mils DFT


Note: Use Series 1090 as the finish coat for high traffic areas

7.0–10.0 mils DFT (excludes spot-prime coats)

Heavy Duty, Chemical Resistant Epoxy


S2.4

Previously painted steel in chemical rooms, laboratories, wash bays and process areas subject to chemical splash or washdown (non-immersion)

Wash clean; SSPC-SP2/SP3 Hand/Power Tool Cleaning; SSPC-SP11 to bare metal at corroded areas; feather transition edges

Touch-Up Primer: Series 1 Omnithane — 2.5–3.5 mils DFT


First Coat: Series 104 H.S. Epoxy — 4.0–6.0 mils DFT


Finish Coat: Series 104 H.S. Epoxy — 4.0–6.0 mils DFT

8.0–12.0 mils DFT (excludes touch-up coats)

Overhead Structural Steel / Joists / Deck, Dry-Fall


S2.5

Previously painted overhead structural steel, joists, deck, ductwork and conduit in open-ceiling spaces (dry-fall application)

Wash clean; SSPC-SP2/SP3 Hand/Power Tool Cleaning to degloss; remove loose coatings; feather transition edges

Spot Prime: Series 135 Chembuild — 4.0–6.0 mils DFT


First Coat: Series 115 Uni-Bond DF — 2.0–4.0 mils DFT


Finish Coat: Series 115 Uni-Bond DF — 2.0–4.0 mils DFT

8.0–14.0 mils DFT

Galvanized Steel, Epoxy Finish


S2.6

Galvanized pipe, handrails, ladders and miscellaneous fabrications — interior, non-immersion service

SSPC-SP1; SSPC-SP2/SP3 to degloss and remove loose coating; SSPC-SP16 at exposed galvanizing

First Coat: Series V69 Hi-Build Epoxoline II — 3.0–4.0 mils DFT


Finish Coat: Series V69 Hi-Build Epoxoline II — 3.0–4.0 mils DFT

6.0–8.0 mils DFT

Galvanized Steel, Urethane Finish


S2.7

Previously painted galvanized railings, stairs, ladders, frames and miscellaneous fabrications in visible interior spaces needing color and gloss retention

SSPC-SP1; SSPC-SP2/SP3 to degloss and remove loose coating; SSPC-SP16 at exposed galvanizing

First Coat: Series V69 Hi-Build Epoxoline II — 3.0–4.0 mils DFT


Finish Coat: Series 1095 Endura-Shield — 3.0–4.0 mils DFT

6.0–8.0 mils DFT

Hollow Metal Doors, Frames, Railings — Light Architectural Duty


S2.8

Previously painted hollow metal doors, frames, railings and trim in offices, corridors, classrooms and other low-abuse interior spaces

Wash clean; SSPC-SP2/SP3 Hand/Power Tool Cleaning to degloss; remove loose coatings; feather transition edges

Primer: Series 1028/1029 Enduratone — 2.0–3.0 mils DFT


Finish Coat: Series 1028/1029 Enduratone — 2.0–3.0 mils DFT

4.0–6.0 mils DFT

Hollow Metal Doors, Frames, Railings — Moderate/Heavy Duty


S2.9

Lobbies, atriums, public areas, assembly spaces, garages, maintenance areas, exposed columns/beams and existing mechanical or support steel

Wash clean; SSPC-SP2/SP3 Hand/Power Tool Cleaning to degloss; remove loose coatings; feather transition edges

Primer: Series 27 Typoxy — 3.0–4.0 mils DFT


Finish Coat: Series 1090 Endura-Shield — 3.0–4.0 mils DFT

6.0–8.0 mils DFT

T1 — GLAZED TILE / GLAZED BLOCK





Light/Moderate Duty


T1.1

Restrooms, kitchens, break rooms, utility rooms and existing tile receiving decorative or light-duty coatings

Clean thoroughly (Simple Green/TSP or similar); uniformly scarify to remove glaze/sheen (test patch recommended)

Primer: Series 108 ProBond — 1.0–2.0 mils DFT


First Coat: Series 1028 Enduratone — 2.0–3.0 mils DFT


Finish Coat: Series 1028 Enduratone — 2.0–3.0 mils DFT

5.0–8.0 mils DFT

Moderate/Heavy Duty, Epoxy w/ Urethane Finish


T1.2

Locker rooms, laboratories, commercial kitchens, service areas and tile requiring enhanced chemical, cleaning or abrasion resistance

Clean thoroughly (Simple Green/TSP or similar); uniformly scarify to remove glaze/sheen (test patch recommended)

Primer: Series 108 ProBond — 1.0–2.0 mils DFT


First Coat: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT


Finish Coat: Series 297 Enviro-Glaze — 2.0–3.0 mils DFT

7.0–11.0 mils DFT

Shower / Wet Walls


T1.3

Showers, locker rooms, wash areas and tiled wet rooms

Clean thoroughly (Simple Green/TSP or similar); uniformly scarify to remove glaze/sheen (test patch recommended)

Primer: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT


First Coat: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT


Finish Coat: Series 297 Enviro-Glaze — 2.0–3.0 mils DFT

10.0–15.0 mils DFT

M1 — MISCELLANEOUS INTERIOR SUBSTRATES





Wood — Bare or Previously Painted


M1.1

Doors, trim, millwork, paneling and exposed architectural wood

Clean and dry; sand smooth; remove loose/peeling paint and feather edges

Primer: Series V10 Tnemec Primer — 2.0–3.5 mils DFT


First Coat: Series 1028/1029 Enduratone — 2.0–3.0 mils DFT


Finish Coat: Series 1028/1029 Enduratone — 2.0–3.0 mils DFT

6.0–9.5 mils DFT

PVC Pipe, Trim and Plastic Components


M1.2

PVC trim, piping, panels and miscellaneous plastic components requiring field coating

Solvent clean and dry; lightly sand with #150-200 sandpaper

First Coat: Series 1028/1029 Enduratone — 2.0–3.0 mils DFT


Finish Coat: Series 1028/1029 Enduratone — 2.0–3.0 mils DFT

4.0–6.0 mils DFT

Insulated Pipe Jacketing (Canvas / PVC Jacket)


M1.3

Canvas or PVC insulated pipe jacketing in mechanical rooms, boiler rooms, corridors and other exposed interior areas

Clean and dry

First Coat: Series 1026 Enduratone — 2.0–3.0 mils DFT


Finish Coat: Series 1026 Enduratone — 2.0–3.0 mils DFT

4.0–6.0 mils DFT

Interior Aluminum and Non-Ferrous Metal


M1.4

Interior aluminum and non-ferrous railings, trim, frames, louvers, grilles and miscellaneous metal components

SSPC-SP1; light abrasive sweep blast or uniformly sand to profile; avoid damaging/warping thin components

Primer: Series 116 Uni-Bond — 2.0–4.0 mils DFT


Finish Coat: Series 1028/1029 Enduratone — 2.0–3.0 mils DFT

4.0–7.0 mils DFT

EXTERIOR SYSTEMS





EC1 — NEW OR PREVIOUSLY UNCOATED CMU AND CONCRETE





Elastomeric / Crack-Bridging, Smooth Finish


EC1.1

Exterior masonry/CMU, unpainted

SSPC-SP13/NACE No. 6; clean, dry, free of oil/grease/form-release agents; allow new concrete/CMU to cure min. 14 days; repair cracks per mfr procedure

Block Filler (CMU, as needed): Series 130 Envirofill — 60–80 SF/gal


Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT


First Coat: Series 156 Enviro-Crete — 6.0–8.0 mils DFT


Finish Coat: Series 156 Enviro-Crete — 6.0–8.0 mils DFT

12.7–17.5 mils DFT (over block filler applied at coverage rate)

Elastomeric / Crack-Bridging, Sand Textured Finish


EC1.2

Exterior CMU and concrete walls, screen walls and building envelopes where a sand-textured elastomeric finish is desired to hide surface irregularities

SSPC-SP13/NACE No. 6; clean, dry, free of oil/grease/form-release agents; allow new concrete/CMU to cure min. 14 days; repair cracks per mfr procedure

Block Filler (CMU, as needed): Series 130 Envirofill — 60–80 SF/gal


Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT


First Coat: Series 156 Enviro-Crete — 6.0–8.0 mils DFT


Finish Coat: Series 157 Enviro-Crete (sand textured) — 6.0–9.0 mils DFT

12.7–18.5 mils DFT (over block filler applied at coverage rate)

EC2 — EXISTING / PREVIOUSLY PAINTED CMU, BRICK AND CONCRETE





Elastomeric / Crack-Bridging Recoat


EC2.1

Building envelopes, exterior CMU/concrete walls, above-grade foundations, screen walls, retaining walls and masonry requiring crack-bridging or weatherproofing

Power wash; remove loose/peeling coating and chalk; clean and dry

Primer (as needed): Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT


First Coat: Series 156 Enviro-Crete — 4.0–6.0 mils DFT


Finish Coat: Series 156 Enviro-Crete — 4.0–6.0 mils DFT

8.0–12.0 mils DFT; optional Primer (as needed) 0.7–1.5

EC3 — STUCCO AND CEMENT PLASTER





Uncoated or Previously Painted


EC3.1

Exterior stucco and cement plaster walls, soffits, parapets and building envelope surfaces

SSPC-SP13 Surface Preparation of Concrete; clean and dry

Primer: Series 151-1051 Elasto-Grip FC — 0.7–1.5 mils DFT


First Coat: Series 156 Enviro-Crete — 4.0–6.0 mils DFT


Finish Coat: Series 156 Enviro-Crete — 4.0–6.0 mils DFT

8.7–13.5 mils DFT

ES1 — NEW OR FULL-COATING-REMOVAL STEEL





Zinc / Epoxy / Urethane (Good)


ES1.1

New fabrication or full coating removal — exterior structural steel, tanks, pipe supports and equipment, non-immersion service

SSPC-SP6/NACE No. 3 Commercial Blast Cleaning

Shop or Field Primer: Series 90-97 Tneme-Zinc — 2.5–3.5 mils DFT


Touch-Up Primer: Series 90G-1K97 Tneme-Zinc — 2.5–3.5 mils DFT


Intermediate: Series V69 Hi-Build Epoxoline II — 4.0–6.0 mils DFT


Finish Coat: Series 1095 Endura-Shield — 3.0–4.0 mils DFT


Note: Use Series 1090 as the finish coat for high traffic areas

9.5–13.5 mils DFT (excludes touch-up coats)

Zinc / Epoxy / Urethane / Fluoropolymer (Best — Extended UV & Color Retention)


ES1.2

Architecturally exposed exterior steel — canopies, entrance structures, pedestrian bridges, light poles, sign structures and tank exteriors where extended color and gloss retention is required

SSPC-SP6/NACE No. 3 Commercial Blast Cleaning

Shop or Field Primer: Series 90-97 Tneme-Zinc — 2.5–3.5 mils DFT


Touch-Up Primer: Series 90G-1K97 Tneme-Zinc — 2.5–3.5 mils DFT


Stripe / Intermediate 1: Series V69 Hi-Build Epoxoline II — 3.0–5.0 mils DFT


Intermediate 2: Series 1095 or 1096 Endura-Shield — 3.0–4.0 mils DFT


Finish Coat: Series 1070/1071/1072 Fluoronar — 2.0–3.0 mils DFT

10.5–15.5 mils DFT (excludes stripe/touch-up coats)

ES2 — EXISTING / PREVIOUSLY PAINTED STEEL (OVERCOAT)





Epoxy Mastic / Urethane (Good)


ES2.1

Existing exterior steel with a sound coating — support steel, equipment, enclosures, fencing, gates, tank exteriors and miscellaneous steel receiving an overcoat

SSPC-SP2/SP3 Hand/Power Tool Cleaning; remove loose coating; feather transition edges

Spot Prime: Series 135 Chembuild — 4.0–6.0 mils DFT


Full Prime Coat: Series 135 Chembuild — 4.0–6.0 mils DFT


Finish Coat: Series 1095 Endura-Shield — 3.0–4.0 mils DFT


Note: Use Series 1090 as the finish coat for high traffic areas

7.0–10.0 mils DFT (excludes spot-prime coats)

Epoxy Mastic / Urethane / Fluoropolymer (Best)


ES2.2

Existing canopies, entrance structures, bridges, support steel, light poles, sign frames, equipment screens and miscellaneous exposed steel where the existing coating remains

SSPC-SP2/SP3 Hand/Power Tool Cleaning; remove loose coating; feather transition edges

Spot Prime: Series 135 Chembuild — 4.0–6.0 mils DFT


Full Prime Coat: Series 135 Chembuild — 4.0–6.0 mils DFT


Intermediate: Series 1095 or 1096 Endura-Shield — 3.0–4.0 mils DFT


Finish Coat: Series 1070/1071/1072 Fluoronar — 2.0–3.0 mils DFT

9.0–13.0 mils DFT (excludes spot-prime coats)

ES3 — GALVANIZED STEEL





New or Full Coating Removal, Urethane Finish (Good)


ES3.1

Exterior galvanized railings, stairs, ladders, canopies, fencing, gates, support steel and miscellaneous galvanized fabrications

SSPC-SP1 to remove oil/grease/contaminants; SSPC-SP16 to remove storage stains and uniformly profile

Primer: Series V69 Hi-Build Epoxoline II — 3.0–4.0 mils DFT


Finish Coat: Series 1095 Endura-Shield — 3.0–4.0 mils DFT

6.0–8.0 mils DFT

New or Full Coating Removal, Fluoropolymer Finish (Best)


ES3.2

Exterior stairs, guards, handrails, canopies, structural supports, sign frames and galvanized assets requiring full refurbishment

Remove existing coating; abrasive blast per SSPC-SP16, min. 1.5-mil angular anchor profile

Spot Primer (repair damaged galvanizing): Series 94-H2O Hydro-Zinc — 2.5–3.5 mils DFT


Primer: Series V69 Hi-Build Epoxoline II — 3.0–4.0 mils DFT


Intermediate: Series 1095 or 1096 Endura-Shield — 2.0–3.0 mils DFT


Finish Coat: Series 1070/1071/1072 Fluoronar — 2.0–3.0 mils DFT

7.0–10.0 mils DFT (excludes spot-prime coats)

Previously Coated Galvanized, Overcoat


ES3.3

Previously coated exterior galvanized railings, ladders, doors and frames, fencing, gates, support poles and miscellaneous galvanized metal

Wash clean; SSPC-SP2/SP3 Hand/Power Tool Cleaning to degloss; remove loose coatings; feather transition edges

Spot / Prime Coat: Series 27 Typoxy — 3.0–4.0 mils DFT


Finish Coat: Series 1095 Endura-Shield — 3.0–4.0 mils DFT


Optional Finish: Series 1070V Fluoronar — 2.0–3.0 mils DFT

6.0–8.0 mils DFT; Optional Finish 2.0–3.0

ES4 — ALUMINUM AND NON-FERROUS METAL





General


ES4.1

Louvers, screens, railings, architectural trim, frames, stairs/platforms and exposed aluminum components

Light abrasive sweep blast (SSPC-SP16), uniform angular profile 1.0-2.0 mils; avoid damaging/warping thin components

Primer: Series V69 Hi-Build Epoxoline II — 2.0–3.0 mils DFT


Intermediate: Series 1095 Endura-Shield — 2.0–3.0 mils DFT


Finish Coat: Series 1071 Fluoronar — 2.0–3.0 mils DFT

6.0–9.0 mils DFT

ES5 — HOLLOW METAL DOORS AND FRAMES





Hollow Metal Doors, Frames, Railings — Light Architectural Duty


ES5.1

Exterior hollow metal doors, frames, railings and trim at entrances, service doors and other light-duty exterior locations

SSPC-SP1; SSPC-SP2/SP3 to degloss and remove loose coating; feather transition edges

Primer: Series 1028/1029 Enduratone — 2.0–3.0 mils DFT


Finish Coat: Series 1028/1029 Enduratone — 2.0–3.0 mils DFT

4.0–6.0 mils DFT

Hollow Metal Doors, Frames, Railings — Moderate/Heavy Duty


ES5.2

Hollow-metal doors, frames, access doors, service doors, overhead-door components and similar ferrous assemblies

SSPC-SP1; SSPC-SP2/SP3 to degloss and remove loose coating; feather transition edges

Primer: Series 27 Typoxy — 3.0–4.0 mils DFT


Finish Coat: Series 1095 Endura-Shield — 3.0–4.0 mils DFT


Note: Use Series 1090 as the finish coat for high traffic areas

6.0–8.0 mils DFT

ES6 — METAL PANEL ROOFS AND WALLS (PREFINISHED / KYNAR)





Best — 15-Year Color and Gloss


ES6.1

Metal roof panels, wall panels, prefinished siding, fascias, copings and weathered factory-finished metal surfaces

Power wash clean in accordance with SSPC-SP1; uniformly scarify to remove glaze/sheen (test patch required)

Primer: Series 108 ProBond — 1.0–2.0 mils DFT


Intermediate: Series 1095 Endura-Shield — 3.0–4.0 mils DFT


Finish Coat: Series 1070V Fluoronar — 2.0–3.0 mils DFT

6.0–9.0 mils DFT

Good — 7-Year Color and Gloss


ES6.2

Metal roof panels, wall panels, prefinished siding, fascias and copings where a heat-reflective finish with a 7-year color and gloss warranty is acceptable

Power wash clean in accordance with SSPC-SP1; uniformly scarify to remove glaze/sheen (test patch required)

Primer: Tex-Cote Metal Prime — 1.0–2.0 mils DFT


Intermediate: Tex-Cote Reflect-Tec — 3.0–4.0 mils DFT


Finish Coat: Tex-Cote Reflect-Tec — 3.0–4.0 mils DFT

7.0–10.0 mils DFT

EW1 — WOOD





Bare or Previously Painted


EW1.1

Doors, trim, millwork, paneling and exposed architectural wood

Clean and dry; sand smooth

Primer: Series V10 Tnemec Primer — 2.0–3.5 mils DFT


First Coat: Series 1028 Enduratone — 2.0–3.0 mils DFT


Finish Coat: Series 1028 Enduratone — 2.0–3.0 mils DFT

6.0–9.5 mils DFT

ED1 — PEDESTRIAN DECK COATINGS (NON-VEHICULAR)





General Waterproofing, Broadcast


ED1.1

Walkways, balconies, plaza decks, breezeways, terraces and non-vehicular concrete decks requiring waterproofing and slip resistance

SSPC-SP13 Surface Preparation of Concrete

Primer: Series 154 TnemeGuard (thinned) — 4.0–7.0 mils DFT


Slurry / Broadcast Coat: Series 154 TnemeGuard with 30/50 silica sand — 10.0–14.0 mils DFT


Optional Grout Coat: Series 154 TnemeGuard — 10.0–14.0 mils DFT


Finish Coat: Series 297 Enviro-Glaze — 2.0–3.0 mils DFT

16.0–24.0 mils DFT; Optional Grout Coat 10.0–14.0

Exposed Concrete Stairs and Elevated Decks, Mesh-Reinforced


ED1.2

Exterior or exposed concrete stairs, landings, ramps, platforms and elevated decks requiring a mesh-reinforced, slip-resistant walking surface

Wash clean; prepare concrete by sanding, light grinding, or pressurized water cleaning at 4,000-5,000 psi w/ zero-degree oscillating tip; clean, dry, sound. Fill hairline cracks (<1/64") by brushing Series 154 in; cracks ≥1/64" or moving cracks/joints — reinforce w/ Series S211 woven mesh.

Steel Spot Prime (as applicable): Series 118 Uni-Bond Mastic — 4.0–6.0 mils DFT


Primer: Series 154 TnemeGuard (thinned) — 4.0–7.0 mils DFT


1st Intermediate: Series 154 TnemeGuard with S211 woven mesh — 10.0–14.0 mils DFT


2nd Intermediate: Series 154 TnemeGuard with silica sand broadcast — 10.0–14.0 mils DFT


Finish Coat: Series 297 Enviro-Glaze — 2.0–3.0 mils DFT

26.0–38.0 mils DFT (excludes spot-prime coats)

ESL1 — WATER REPELLENTS, SEALERS AND ANTI-GRAFFITI





Penetrating Silane/Siloxane Water Repellent


ESL1.1

Exterior concrete, precast, brick, block, stone, stucco and other absorptive masonry exposed to weather; clear penetrating water repellent with no film build

Per product surface-absorption test; clean, dry, free of efflorescence

Sealer: Series 633 Prime-A-Pell H2O (Tnemec) — or Tex-Cote Rainstopper 120/140 — N/A (penetrating sealer)

Not applicable — penetrating sealer, no measurable dry film thickness

Anti-Graffiti (Sacrificial / Non-Sacrificial)


ESL1.2

Exterior masonry, concrete and coated walls at grade level, entrances, underpasses and other areas subject to graffiti

Clean and dry; if previously coated, uniformly scarify to sound coating

Primer (porous masonry only): Rainstopper 1750W Clear Sealer (TEX-COTE) — Applied at coverage rate


Topcoat: Graffiti Gard IV (TEX-COTE) — 250–350 SF/gal clear; 150–200 SF/gal pigmented

Not specified — system applied by coverage rate; see coat schedule

SPECIALTY SYSTEMS





X1 — SPECIALTY SYSTEMS





Aerogel Thermal-Break Coating at Steel Envelope Penetrations


X1.1

Steel penetrating the building envelope — relieving angles, lintels, canopy and balcony steel and other thermal-bridge locations

SSPC-SP6/NACE No. 3 Commercial Blast Cleaning

Primer: Series 394 PerimePrime — 2.5–3.5 mils DFT


Insulative Coating (2–3 coats by shape): Series 971 Aerolon — 40.0–50.0 per coat (2 coats W-shapes / 3 coats HSS & deck)


Finish (exposed to view): Series 1028 Enduratone — 2.0–3.0 mils DFT

80–150 mils DFT (per shape; 2 coats W-shapes, 3 coats HSS/deck) plus 2.0–3.0 finish where exposed

Where to Go Next

  • For CSI 3-part bid/construction specification language built from these same systems, use Section 09 96 00, High-Performance Coatings, or contact Atlantic Coating Consultants for a project-specific specification.

  • For resinous flooring, use the companion Short-Form System Reference Guide — Resinous Flooring and Section 09 67 23. For process-facility applications, use the companion Water Treatment and Wastewater Treatment Short-Form System Reference guides.

  • For pool/aquatic linings, secondary containment, potable-water or wastewater immersion systems, or specialty exposures not covered here, contact Atlantic Coating Consultants.

Prepared as a service by: Atlantic Coating Consultants | Wally Bates | atlantic@tnemec.com | 484-644-5303


Recent Posts

See All

Comments


  • Grey Twitter Icon
  • Grey LinkedIn Icon
  • Grey Facebook Icon

© 2026 Atlantic Coating Consultants · 108 Oak Creek Dr., Royersford, PA 19468 · 484-644-5303

bottom of page